Auto
SCPI Command :
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:AUTO
- class AutoCls[source]
Auto commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(window=Window.Default, trace=Trace.Default) bool [source]
# SCPI: DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:AUTO value: bool = driver.applications.k9X11Ad.display.window.trace.y.scale.auto.get(window = repcap.Window.Default, trace = repcap.Trace.Default)
Activates or deactivates automatic scaling of the x-axis or y-axis for the specified trace display. This command is currently only supported for Amplitude Modulation measurements.
- param window
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Window’)
- param trace
optional repeated capability selector. Default value: Tr1 (settable in the interface ‘Trace’)
- return
auto: ON | OFF | 0 | 1 OFF | 0 The x-axis or y-axis is scaled according to the specified minimum/maximum values (see method RsFsw.Applications.K50_Spurious.Display.Window.Trace.Y.Scale.Minimum.set/method RsFsw.Applications.K50_Spurious.Display.Window.Trace.Y.Scale.Maximum.set) and number of divisions (see method RsFsw.Applications.K91_Wlan.Display.Window.Subwindow.Trace.Y.Scale.Divisions.set) . ON | 1 The R&S FSW WLAN application automatically scales the x-axis or y-axis to best fit the measurement results.
- set(auto: bool, window=Window.Default, trace=Trace.Default) None [source]
# SCPI: DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:AUTO driver.applications.k9X11Ad.display.window.trace.y.scale.auto.set(auto = False, window = repcap.Window.Default, trace = repcap.Trace.Default)
Activates or deactivates automatic scaling of the x-axis or y-axis for the specified trace display. This command is currently only supported for Amplitude Modulation measurements.
- param auto
ON | OFF | 0 | 1 OFF | 0 The x-axis or y-axis is scaled according to the specified minimum/maximum values (see method RsFsw.Applications.K50_Spurious.Display.Window.Trace.Y.Scale.Minimum.set/method RsFsw.Applications.K50_Spurious.Display.Window.Trace.Y.Scale.Maximum.set) and number of divisions (see method RsFsw.Applications.K91_Wlan.Display.Window.Subwindow.Trace.Y.Scale.Divisions.set) . ON | 1 The R&S FSW WLAN application automatically scales the x-axis or y-axis to best fit the measurement results.
- param window
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Window’)
- param trace
optional repeated capability selector. Default value: Tr1 (settable in the interface ‘Trace’)