Source code for RsFsw.Implementations.Applications.K9x_11ad.Display.Window.Trace.Y.Scale.Auto

from .........Internal.Core import Core
from .........Internal.CommandsGroup import CommandsGroup
from .........Internal import Conversions
from ......... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class AutoCls: """Auto commands group definition. 1 total commands, 0 Subgroups, 1 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("auto", core, parent)
[docs] def set(self, auto: bool, window=repcap.Window.Default, trace=repcap.Trace.Default) -> None: """SCPI: DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:AUTO \n Snippet: driver.applications.k9X11Ad.display.window.trace.y.scale.auto.set(auto = False, window = repcap.Window.Default, trace = repcap.Trace.Default) \n Activates or deactivates automatic scaling of the x-axis or y-axis for the specified trace display. This command is currently only supported for Amplitude Modulation measurements. \n :param auto: ON | OFF | 0 | 1 OFF | 0 The x-axis or y-axis is scaled according to the specified minimum/maximum values (see method RsFsw.Applications.K50_Spurious.Display.Window.Trace.Y.Scale.Minimum.set/method RsFsw.Applications.K50_Spurious.Display.Window.Trace.Y.Scale.Maximum.set) and number of divisions (see method RsFsw.Applications.K91_Wlan.Display.Window.Subwindow.Trace.Y.Scale.Divisions.set) . ON | 1 The R&S FSW WLAN application automatically scales the x-axis or y-axis to best fit the measurement results. :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Window') :param trace: optional repeated capability selector. Default value: Tr1 (settable in the interface 'Trace') """ param = Conversions.bool_to_str(auto) window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) trace_cmd_val = self._cmd_group.get_repcap_cmd_value(trace, repcap.Trace) self._core.io.write(f'DISPlay:WINDow{window_cmd_val}:TRACe{trace_cmd_val}:Y:SCALe:AUTO {param}')
[docs] def get(self, window=repcap.Window.Default, trace=repcap.Trace.Default) -> bool: """SCPI: DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:AUTO \n Snippet: value: bool = driver.applications.k9X11Ad.display.window.trace.y.scale.auto.get(window = repcap.Window.Default, trace = repcap.Trace.Default) \n Activates or deactivates automatic scaling of the x-axis or y-axis for the specified trace display. This command is currently only supported for Amplitude Modulation measurements. \n :param window: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Window') :param trace: optional repeated capability selector. Default value: Tr1 (settable in the interface 'Trace') :return: auto: ON | OFF | 0 | 1 OFF | 0 The x-axis or y-axis is scaled according to the specified minimum/maximum values (see method RsFsw.Applications.K50_Spurious.Display.Window.Trace.Y.Scale.Minimum.set/method RsFsw.Applications.K50_Spurious.Display.Window.Trace.Y.Scale.Maximum.set) and number of divisions (see method RsFsw.Applications.K91_Wlan.Display.Window.Subwindow.Trace.Y.Scale.Divisions.set) . ON | 1 The R&S FSW WLAN application automatically scales the x-axis or y-axis to best fit the measurement results.""" window_cmd_val = self._cmd_group.get_repcap_cmd_value(window, repcap.Window) trace_cmd_val = self._cmd_group.get_repcap_cmd_value(trace, repcap.Trace) response = self._core.io.query_str(f'DISPlay:WINDow{window_cmd_val}:TRACe{trace_cmd_val}:Y:SCALe:AUTO?') return Conversions.str_to_bool(response)