Pattern

SCPI Command :

CONFigure[:NR5G]:DL[:CC<cc>]:SSBLock:PATTern
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(carrierComponent=CarrierComponent.Default) SyncSignalPattern[source]
# CONFigure[:NR5G]:DL[:CC<cc>]:SSBLock:PATTern
value: enums.SyncSignalPattern = driver.applications.k14Xnr5G.configure.nr5G.downlink.cc.ssBlock.pattern.get(carrierComponent = repcap.CarrierComponent.Default)

Selects the pattern of a synchronization signal block. Prerequisites for this command

  • Select manual configuration mode for SS (method RsFsw.applications.k14Xnr5G.configure.nr5G.downlink.cc.ssBlock.detection.set() ) .

Parameters:

carrierComponent – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cc’)

Returns:

pattern: A | B | C | D | E | F | G The SSB patterns are linked to the subcarrier spacing. Patterns A, D, E, F and G cannot be set. They are always selected automatically when you select a subcarrier spacing of 15 kHz (pattern A) , 120 kHz (pattern D) , 240 kHz (pattern E) , 480 kHz (pattern F) or 960 kHz (pattern G) . For these subcarrier spacing, the command is a query only. For subcarrier spacing of 30 kHz, you can select pattern B or C.

set(pattern: SyncSignalPattern, carrierComponent=CarrierComponent.Default) None[source]
# CONFigure[:NR5G]:DL[:CC<cc>]:SSBLock:PATTern
driver.applications.k14Xnr5G.configure.nr5G.downlink.cc.ssBlock.pattern.set(pattern = enums.SyncSignalPattern.A, carrierComponent = repcap.CarrierComponent.Default)

Selects the pattern of a synchronization signal block. Prerequisites for this command

  • Select manual configuration mode for SS (method RsFsw.applications.k14Xnr5G.configure.nr5G.downlink.cc.ssBlock.detection.set() ) .

Parameters:
  • pattern – A | B | C | D | E | F | G The SSB patterns are linked to the subcarrier spacing. Patterns A, D, E, F and G cannot be set. They are always selected automatically when you select a subcarrier spacing of 15 kHz (pattern A) , 120 kHz (pattern D) , 240 kHz (pattern E) , 480 kHz (pattern F) or 960 kHz (pattern G) . For these subcarrier spacing, the command is a query only. For subcarrier spacing of 30 kHz, you can select pattern B or C.

  • carrierComponent – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cc’)