Measurement
SCPI Command :
CONFigure[:NR5G]:MEASurement
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get() MeasurementNr5G[source]
# CONFigure[:NR5G]:MEASurement value: enums.MeasurementNr5G = driver.applications.k14Xnr5G.configure.nr5G.measurement.get()
Selects the measurement type.
- Returns:
measurement: ACLR Selects the adjacent channel leakage ratio (ACLR) measurement. CACLr Selects the Cumulative ACLR measurement. CMEasurement Selects combined EVM / ACLR / SEM measurement. ESPectrum Selects the spectrum emission mask (SEM) measurement. EVM Selects I/Q measurements. MCAClr Selects Multi-Carrier ACLR measurement. MCESpectrum Selects Multi-Carrier SEM measurement. TAERor Selects the time alignment error measurement. TPOO Selects the transmit on / off power measurement.
- set(measurement: MeasurementNr5G) None[source]
# CONFigure[:NR5G]:MEASurement driver.applications.k14Xnr5G.configure.nr5G.measurement.set(measurement = enums.MeasurementNr5G.ACLR)
Selects the measurement type.
- Parameters:
measurement – ACLR Selects the adjacent channel leakage ratio (ACLR) measurement. CACLr Selects the Cumulative ACLR measurement. CMEasurement Selects combined EVM / ACLR / SEM measurement. ESPectrum Selects the spectrum emission mask (SEM) measurement. EVM Selects I/Q measurements. MCAClr Selects Multi-Carrier ACLR measurement. MCESpectrum Selects Multi-Carrier SEM measurement. TAERor Selects the time alignment error measurement. TPOO Selects the transmit on / off power measurement.