Period
SCPI Command :
CONFigure[:NR5G]:DL[:CC<cc>]:FRAMe<fr>:BWPart<bwp>:SLOT<sl>:PASTe:TO:PERiod
- class PeriodCls[source]
Period commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(carrierComponent=CarrierComponent.Default, frame=Frame.Default, bwPart=BwPart.Default, slot=Slot.Default) float [source]
# SCPI: CONFigure[:NR5G]:DL[:CC<cc>]:FRAMe<fr>:BWPart<bwp>:SLOT<sl>:PASTe:TO:PERiod value: float = driver.applications.k14Xnr5G.configure.nr5G.downlink.cc.frame.bwPart.slot.paste.to.period.get(carrierComponent = repcap.CarrierComponent.Default, frame = repcap.Frame.Default, bwPart = repcap.BwPart.Default, slot = repcap.Slot.Default)
- Defines to which slots a slot configuration is copied to.
INTRO_CMD_HELP: Prerequisites for this command
A slot configuration is in the clipboard (method RsFsw.Applications.K14x_Nr5G.Configure.Nr5G.Downlink.Cc.Frame.BwPart.Slot.copy) .
Number of configurable slots > 1 (method RsFsw.Applications.K14x_Nr5G.Configure.Nr5G.Downlink.Cc.Frame.BwPart.Cslot.set) .
Select custom paste mode (method RsFsw.Applications.K14x_Nr5G.Configure.Nr5G.Downlink.Cc.Frame.BwPart.Slot.Paste.To.Mode.set) .
- param carrierComponent
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cc’)
- param frame
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Frame’)
- param bwPart
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘BwPart’)
- param slot
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Slot’)
- return
period: The paste period corresponds to every nth slot.
- set(period: float, carrierComponent=CarrierComponent.Default, frame=Frame.Default, bwPart=BwPart.Default, slot=Slot.Default) None [source]
# SCPI: CONFigure[:NR5G]:DL[:CC<cc>]:FRAMe<fr>:BWPart<bwp>:SLOT<sl>:PASTe:TO:PERiod driver.applications.k14Xnr5G.configure.nr5G.downlink.cc.frame.bwPart.slot.paste.to.period.set(period = 1.0, carrierComponent = repcap.CarrierComponent.Default, frame = repcap.Frame.Default, bwPart = repcap.BwPart.Default, slot = repcap.Slot.Default)
- Defines to which slots a slot configuration is copied to.
INTRO_CMD_HELP: Prerequisites for this command
A slot configuration is in the clipboard (method RsFsw.Applications.K14x_Nr5G.Configure.Nr5G.Downlink.Cc.Frame.BwPart.Slot.copy) .
Number of configurable slots > 1 (method RsFsw.Applications.K14x_Nr5G.Configure.Nr5G.Downlink.Cc.Frame.BwPart.Cslot.set) .
Select custom paste mode (method RsFsw.Applications.K14x_Nr5G.Configure.Nr5G.Downlink.Cc.Frame.BwPart.Slot.Paste.To.Mode.set) .
- param period
The paste period corresponds to every nth slot.
- param carrierComponent
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cc’)
- param frame
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Frame’)
- param bwPart
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘BwPart’)
- param slot
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Slot’)