Source code for RsSmw.Implementations.Source.Bb.C2K.Bstation.Cgroup.Coffset.Tpc.Read

from .........Internal.Core import Core
from .........Internal.CommandsGroup import CommandsGroup
from .........Internal import Conversions
from ......... import enums
from ......... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class ReadCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("read", core, parent)

[docs] def set(self, read: enums.TpcReadMode, baseStation=repcap.BaseStation.Default, groupNull=repcap.GroupNull.Default, offset=repcap.Offset.Default) -> None: """ ``[SOURce<HW>]:BB:C2K:BSTation<ST>:CGRoup<DI0>:COFFset<CH>:TPC:READ`` \n Snippet: ``driver.source.bb.c2K.bstation.cgroup.coffset.tpc.read.set(read = enums.TpcReadMode.CONTinuous, baseStation = repcap.BaseStation.Default, groupNull = repcap.GroupNull.Default, offset = repcap.Offset.Default)`` \n The command sets the read out mode for the bit pattern of the power control bits. The bit pattern is defined with the commands BB:C2K:BST<n>:CGRoup<n>:COFFset<n>:TPC.... Power control is available for sub channel types F-DCCH and F-FCH. F-DCCH is only generated for radio configurations 3, 4 and 5. For the traffic channels, this value is specific for the selected radio configuration. :param read: CONTinuous | S0A | S1A | S01A | S10A CONTinuous The bit pattern is used cyclically. S0A The bit pattern is used once, then the power control bit sequence continues with 0 bits. S1A The bit pattern is used once, then the power control bit sequence continues with 1 bit. S01A The bit pattern is used once and then the power control bit sequence is continued with 0 bits and 1 bit alternately. S10A The bit pattern is used once and then the power control bit sequence is continued with 1 bit and 0 bits alternately. :param baseStation: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Bstation') :param groupNull: optional repeated capability selector. Default value: Nr0 (settable in the interface 'Cgroup') :param offset: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Coffset') """ param = Conversions.enum_scalar_to_str(read, enums.TpcReadMode) baseStation_cmd_val = self._cmd_group.get_repcap_cmd_value(baseStation, repcap.BaseStation) groupNull_cmd_val = self._cmd_group.get_repcap_cmd_value(groupNull, repcap.GroupNull) offset_cmd_val = self._cmd_group.get_repcap_cmd_value(offset, repcap.Offset) self._core.io.write(f'SOURce<HwInstance>:BB:C2K:BSTation{baseStation_cmd_val}:CGRoup{groupNull_cmd_val}:COFFset{offset_cmd_val}:TPC:READ {param}')
# noinspection PyTypeChecker
[docs] def get(self, baseStation=repcap.BaseStation.Default, groupNull=repcap.GroupNull.Default, offset=repcap.Offset.Default) -> enums.TpcReadMode: """ ``[SOURce<HW>]:BB:C2K:BSTation<ST>:CGRoup<DI0>:COFFset<CH>:TPC:READ`` \n Snippet: ``value: enums.TpcReadMode = driver.source.bb.c2K.bstation.cgroup.coffset.tpc.read.get(baseStation = repcap.BaseStation.Default, groupNull = repcap.GroupNull.Default, offset = repcap.Offset.Default)`` \n The command sets the read out mode for the bit pattern of the power control bits. The bit pattern is defined with the commands BB:C2K:BST<n>:CGRoup<n>:COFFset<n>:TPC.... Power control is available for sub channel types F-DCCH and F-FCH. F-DCCH is only generated for radio configurations 3, 4 and 5. For the traffic channels, this value is specific for the selected radio configuration. :param baseStation: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Bstation') :param groupNull: optional repeated capability selector. Default value: Nr0 (settable in the interface 'Cgroup') :param offset: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Coffset') :return: read: CONTinuous | S0A | S1A | S01A | S10A CONTinuous The bit pattern is used cyclically. S0A The bit pattern is used once, then the power control bit sequence continues with 0 bits. S1A The bit pattern is used once, then the power control bit sequence continues with 1 bit. S01A The bit pattern is used once and then the power control bit sequence is continued with 0 bits and 1 bit alternately. S10A The bit pattern is used once and then the power control bit sequence is continued with 1 bit and 0 bits alternately. """ baseStation_cmd_val = self._cmd_group.get_repcap_cmd_value(baseStation, repcap.BaseStation) groupNull_cmd_val = self._cmd_group.get_repcap_cmd_value(groupNull, repcap.GroupNull) offset_cmd_val = self._cmd_group.get_repcap_cmd_value(offset, repcap.Offset) response = self._core.io.query_str(f'SOURce<HwInstance>:BB:C2K:BSTation{baseStation_cmd_val}:CGRoup{groupNull_cmd_val}:COFFset{offset_cmd_val}:TPC:READ?') return Conversions.str_to_scalar_enum(response, enums.TpcReadMode)