Read

SCPI Command :

[SOURce<HW>]:BB:C2K:BSTation<ST>:CGRoup<DI0>:COFFset<CH>:TPC:READ
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(baseStation=BaseStation.Default, groupNull=GroupNull.Default, offset=Offset.Default) TpcReadMode[source]
# [SOURce<HW>]:BB:C2K:BSTation<ST>:CGRoup<DI0>:COFFset<CH>:TPC:READ
value: enums.TpcReadMode = driver.source.bb.c2K.bstation.cgroup.coffset.tpc.read.get(baseStation = repcap.BaseStation.Default, groupNull = repcap.GroupNull.Default, offset = repcap.Offset.Default)

The command sets the read out mode for the bit pattern of the power control bits. The bit pattern is defined with the commands BB:C2K:BST<n>:CGRoup<n>:COFFset<n>:TPC…. Power control is available for sub channel types F-DCCH and F-FCH. F-DCCH is only generated for radio configurations 3, 4 and 5. For the traffic channels, this value is specific for the selected radio configuration.

Parameters:
  • baseStation – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Bstation’)

  • groupNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cgroup’)

  • offset – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Coffset’)

Returns:

read: CONTinuous | S0A | S1A | S01A | S10A CONTinuous The bit pattern is used cyclically. S0A The bit pattern is used once, then the power control bit sequence continues with 0 bits. S1A The bit pattern is used once, then the power control bit sequence continues with 1 bit. S01A The bit pattern is used once and then the power control bit sequence is continued with 0 bits and 1 bit alternately. S10A The bit pattern is used once and then the power control bit sequence is continued with 1 bit and 0 bits alternately.

set(read: TpcReadMode, baseStation=BaseStation.Default, groupNull=GroupNull.Default, offset=Offset.Default) None[source]
# [SOURce<HW>]:BB:C2K:BSTation<ST>:CGRoup<DI0>:COFFset<CH>:TPC:READ
driver.source.bb.c2K.bstation.cgroup.coffset.tpc.read.set(read = enums.TpcReadMode.CONTinuous, baseStation = repcap.BaseStation.Default, groupNull = repcap.GroupNull.Default, offset = repcap.Offset.Default)

The command sets the read out mode for the bit pattern of the power control bits. The bit pattern is defined with the commands BB:C2K:BST<n>:CGRoup<n>:COFFset<n>:TPC…. Power control is available for sub channel types F-DCCH and F-FCH. F-DCCH is only generated for radio configurations 3, 4 and 5. For the traffic channels, this value is specific for the selected radio configuration.

Parameters:
  • read – CONTinuous | S0A | S1A | S01A | S10A CONTinuous The bit pattern is used cyclically. S0A The bit pattern is used once, then the power control bit sequence continues with 0 bits. S1A The bit pattern is used once, then the power control bit sequence continues with 1 bit. S01A The bit pattern is used once and then the power control bit sequence is continued with 0 bits and 1 bit alternately. S10A The bit pattern is used once and then the power control bit sequence is continued with 1 bit and 0 bits alternately.

  • baseStation – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Bstation’)

  • groupNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cgroup’)

  • offset – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Coffset’)