SymbolRate

SCPI Command :

[SOURce<HW>]:BB:W3GPp:MSTation<ST>:PCPCh:SRATe
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(mobileStation=MobileStation.Default) SymbRate[source]
# [SOURce<HW>]:BB:W3GPp:MSTation<ST>:PCPCh:SRATe
value: enums.SymbRate = driver.source.bb.w3Gpp.mstation.pcpch.symbolRate.get(mobileStation = repcap.MobileStation.Default)

The command sets the symbol rate of the PCPCH. User Equipment 1: When channel coding is active, the symbol rate is limited to the range between 15 and 120 ksps. Values above this limit are automatically set to 120 ksps.

Parameters:

mobileStation – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mstation’)

Returns:

srate: D15K | D30K | D60K | D120k | D240k | D480k | D960k

set(srate: SymbRate, mobileStation=MobileStation.Default) None[source]
# [SOURce<HW>]:BB:W3GPp:MSTation<ST>:PCPCh:SRATe
driver.source.bb.w3Gpp.mstation.pcpch.symbolRate.set(srate = enums.SymbRate.D120k, mobileStation = repcap.MobileStation.Default)

The command sets the symbol rate of the PCPCH. User Equipment 1: When channel coding is active, the symbol rate is limited to the range between 15 and 120 ksps. Values above this limit are automatically set to 120 ksps.

Parameters:
  • srate – D15K | D30K | D60K | D120k | D240k | D480k | D960k

  • mobileStation – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mstation’)