Sformat
SCPI Command :
[SOURce<HW>]:BB:W3GPp:MSTation<ST>:DPCCh:SFORmat
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(mobileStation=MobileStation.Default) int[source]
# [SOURce<HW>]:BB:W3GPp:MSTation<ST>:DPCCh:SFORmat value: int = driver.source.bb.w3Gpp.mstation.dpcch.sformat.get(mobileStation = repcap.MobileStation.Default)
The command sets the slot format for the DPCCH. The slot format defines the structure of the DPCCH slots and the control fields. Slot Format # 4 is available only for instruments equipped with R&S SMW-K83. Slot formats 0 to 4 are available for the DPCCH channel as defined in the 3GPP Release 7 specification TS 25.211. Note: The former slot formats 4 and 5 according to 3GPP Release 4 specification TS 25.211 are not supported any more. The command sets the FBI mode (method
RsSmw.source.bb.w3Gpp.mstation.dpcch.fbi.mode.set()) , the TFCI status (methodRsSmw.source.bb.w3Gpp.mstation.dpcch.tfci.state.set()) and the TPC Mode (methodRsSmw.source.bb.w3Gpp.mstation.dpcch.tpc.mode.set()) to the associated values.- Parameters:
mobileStation – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mstation’)
- Returns:
sformat: integer Range: 0 to 4
- set(sformat: int, mobileStation=MobileStation.Default) None[source]
# [SOURce<HW>]:BB:W3GPp:MSTation<ST>:DPCCh:SFORmat driver.source.bb.w3Gpp.mstation.dpcch.sformat.set(sformat = 1, mobileStation = repcap.MobileStation.Default)
The command sets the slot format for the DPCCH. The slot format defines the structure of the DPCCH slots and the control fields. Slot Format # 4 is available only for instruments equipped with R&S SMW-K83. Slot formats 0 to 4 are available for the DPCCH channel as defined in the 3GPP Release 7 specification TS 25.211. Note: The former slot formats 4 and 5 according to 3GPP Release 4 specification TS 25.211 are not supported any more. The command sets the FBI mode (method
RsSmw.source.bb.w3Gpp.mstation.dpcch.fbi.mode.set()) , the TFCI status (methodRsSmw.source.bb.w3Gpp.mstation.dpcch.tfci.state.set()) and the TPC Mode (methodRsSmw.source.bb.w3Gpp.mstation.dpcch.tpc.mode.set()) to the associated values.- Parameters:
sformat – integer Range: 0 to 4
mobileStation – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mstation’)