Tgpl

SCPI Command :

[SOURce<HW>]:BB:W3GPp:MSTation<ST>:CMODe:PATTern<CH>:TGPL
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(mobileStation=MobileStation.Default, patternIx=PatternIx.Default) int[source]
# [SOURce<HW>]:BB:W3GPp:MSTation<ST>:CMODe:PATTern<CH>:TGPL
value: int = driver.source.bb.w3Gpp.mstation.cmode.pattern.tgpl.get(mobileStation = repcap.MobileStation.Default, patternIx = repcap.PatternIx.Default)

The command sets the transmission gap pattern lengths. Setting 0 is available only for pattern 2. The transmission gap pattern lengths of the base station with the same suffix as the selected user equipment is set to the same value.

Parameters:
  • mobileStation – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mstation’)

  • patternIx – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Pattern’)

Returns:

tgpl: integer Range: 0 to 100

set(tgpl: int, mobileStation=MobileStation.Default, patternIx=PatternIx.Default) None[source]
# [SOURce<HW>]:BB:W3GPp:MSTation<ST>:CMODe:PATTern<CH>:TGPL
driver.source.bb.w3Gpp.mstation.cmode.pattern.tgpl.set(tgpl = 1, mobileStation = repcap.MobileStation.Default, patternIx = repcap.PatternIx.Default)

The command sets the transmission gap pattern lengths. Setting 0 is available only for pattern 2. The transmission gap pattern lengths of the base station with the same suffix as the selected user equipment is set to the same value.

Parameters:
  • tgpl – integer Range: 0 to 100

  • mobileStation – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mstation’)

  • patternIx – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Pattern’)