Tgpl

SCPI Command :

[SOURce<HW>]:BB:W3GPp:BSTation<ST>:CMODe:PATTern<CH>:TGPL
class TgplCls[source]

Tgpl commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get(baseStation=BaseStation.Default, patternIx=PatternIx.Default) int[source]
# SCPI: [SOURce<HW>]:BB:W3GPp:BSTation<ST>:CMODe:PATTern<CH>:TGPL
value: int = driver.source.bb.w3Gpp.bstation.cmode.pattern.tgpl.get(baseStation = repcap.BaseStation.Default, patternIx = repcap.PatternIx.Default)

The command sets the transmission gap pattern lengths. Setting 0 is available only for pattern 2. The transmission gap pattern length of the user equipment with the same suffix as the selected base station is set to the same value.

param baseStation:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Bstation’)

param patternIx:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Pattern’)

return:

tgpl: integer Range: 0 to 100

set(tgpl: int, baseStation=BaseStation.Default, patternIx=PatternIx.Default) None[source]
# SCPI: [SOURce<HW>]:BB:W3GPp:BSTation<ST>:CMODe:PATTern<CH>:TGPL
driver.source.bb.w3Gpp.bstation.cmode.pattern.tgpl.set(tgpl = 1, baseStation = repcap.BaseStation.Default, patternIx = repcap.PatternIx.Default)

The command sets the transmission gap pattern lengths. Setting 0 is available only for pattern 2. The transmission gap pattern length of the user equipment with the same suffix as the selected base station is set to the same value.

param tgpl:

integer Range: 0 to 100

param baseStation:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Bstation’)

param patternIx:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Pattern’)