Trigger
SCPI Commands :
[SOURce<HW>]:BB:PRAMp:TRIGger:RMODe
[SOURce<HW>]:BB:PRAMp:TRIGger:SLENgth
[SOURce<HW>]:BB:PRAMp:TRIGger:SLUNit
[SOURce<HW>]:BB:PRAMp:TRIGger:SOURce
[SOURce<HW>]:BB:PRAMp:[TRIGger]:SEQuence
- Commands in total: 17Subgroups: 6Direct child commands: 5
- get_rmode() TrigRunMode[source]
# [SOURce<HW>]:BB:PRAMp:TRIGger:RMODe value: enums.TrigRunMode = driver.source.bb.pramp.trigger.get_rmode()
Queries the status of signal generation.
- Returns:
rmode: STOP | RUN
- get_sequence() DmTrigMode[source]
# [SOURce<HW>]:BB:PRAMp:[TRIGger]:SEQuence value: enums.DmTrigMode = driver.source.bb.pramp.trigger.get_sequence()
Selects the trigger mode:
AUTO = auto
RETRigger = retrigger
AAUTo = armed auto
ARETrigger = armed retrigger
SINGle = single
Selects the trigger mode.
- Returns:
sequence: AUTO | RETRigger | AAUTo | ARETrigger | SINGle
- get_sl_unit() UnitSlDvb[source]
# [SOURce<HW>]:BB:PRAMp:TRIGger:SLUNit value: enums.UnitSlDvb = driver.source.bb.pramp.trigger.get_sl_unit()
Defines the unit for the entry of the length of the signal sequence to be output in the Single trigger mode, see method
RsSmw.source.bb.pramp.trigger.sequence().- Returns:
sl_unit: FRAMe | SEQuence FRAMe Unit Frame. A single frame is generated after a trigger event. SEQuence Unit Sequence Length. A single sequence is generated after a trigger event.
- get_slength() int[source]
# [SOURce<HW>]:BB:PRAMp:TRIGger:SLENgth value: int = driver.source.bb.pramp.trigger.get_slength()
Defines the length of the signal sequence to be output in the SINGle trigger mode, see method
RsSmw.source.bb.pramp.trigger.sequence().- Returns:
slength: integer Range: 1 to 7000, Unit: symbol
- get_source() TrigSour[source]
# [SOURce<HW>]:BB:PRAMp:TRIGger:SOURce value: enums.TrigSour = driver.source.bb.pramp.trigger.get_source()
Selects the trigger signal source and determines the way the triggering is executed. Provided are the following trigger sources:
INTernal: Internal manual triggering of the instrument
INTA | INTB: Internal triggering by a signal from the other basebands
External trigger signal via one of the local or global connectors:
EGT1 | EGT2: External global trigger
EGC1 | EGC2: External global clock
ELTRigger: External local trigger
ELCLock: External local clock
For secondary instruments (SCONfiguration:MULTiinstrument:MODE SEC) , triggering
- via the external baseband synchronization signal of the primary instrument: SOURce1:BB:ARB:TRIGger:SOURce BBSY
OBASeband | BEXTernal | EXTernal: Setting only Provided only for backward
compatibility with other Rohde & Schwarz signal generators. The R&S SMW200A accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
- Returns:
source: INTernal | EGT1 | EXTernal | EGC1 | INTB | OBASeband | ELTRigger | EGT2 | EGC2 | INTA | ELCLock | BEXTernal
- set_sequence(sequence: DmTrigMode) None[source]
# [SOURce<HW>]:BB:PRAMp:[TRIGger]:SEQuence driver.source.bb.pramp.trigger.set_sequence(sequence = enums.DmTrigMode.AAUTo)
Selects the trigger mode:
AUTO = auto
RETRigger = retrigger
AAUTo = armed auto
ARETrigger = armed retrigger
SINGle = single
Selects the trigger mode.
- Parameters:
sequence – AUTO | RETRigger | AAUTo | ARETrigger | SINGle
- set_sl_unit(sl_unit: UnitSlDvb) None[source]
# [SOURce<HW>]:BB:PRAMp:TRIGger:SLUNit driver.source.bb.pramp.trigger.set_sl_unit(sl_unit = enums.UnitSlDvb.FRAMe)
Defines the unit for the entry of the length of the signal sequence to be output in the Single trigger mode, see method
RsSmw.source.bb.pramp.trigger.sequence().- Parameters:
sl_unit – FRAMe | SEQuence FRAMe Unit Frame. A single frame is generated after a trigger event. SEQuence Unit Sequence Length. A single sequence is generated after a trigger event.
- set_slength(slength: int) None[source]
# [SOURce<HW>]:BB:PRAMp:TRIGger:SLENgth driver.source.bb.pramp.trigger.set_slength(slength = 1)
Defines the length of the signal sequence to be output in the SINGle trigger mode, see method
RsSmw.source.bb.pramp.trigger.sequence().- Parameters:
slength – integer Range: 1 to 7000, Unit: symbol
- set_source(source: TrigSour) None[source]
# [SOURce<HW>]:BB:PRAMp:TRIGger:SOURce driver.source.bb.pramp.trigger.set_source(source = enums.TrigSour.BBSY)
Selects the trigger signal source and determines the way the triggering is executed. Provided are the following trigger sources:
INTernal: Internal manual triggering of the instrument
INTA | INTB: Internal triggering by a signal from the other basebands
External trigger signal via one of the local or global connectors:
EGT1 | EGT2: External global trigger
EGC1 | EGC2: External global clock
ELTRigger: External local trigger
ELCLock: External local clock
For secondary instruments (SCONfiguration:MULTiinstrument:MODE SEC) , triggering
- via the external baseband synchronization signal of the primary instrument: SOURce1:BB:ARB:TRIGger:SOURce BBSY
OBASeband | BEXTernal | EXTernal: Setting only Provided only for backward
compatibility with other Rohde & Schwarz signal generators. The R&S SMW200A accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
- Parameters:
source – INTernal | EGT1 | EXTernal | EGC1 | INTB | OBASeband | ELTRigger | EGT2 | EGC2 | INTA | ELCLock | BEXTernal
Cloning the Group
# Create a copy of the original group, that exists independently
trigger_copy = driver.source.bb.pramp.trigger.clone()
Subgroups