Trigger
SCPI Commands :
[SOURce<HW>]:BB:GBAS:TRIGger:RMODe
[SOURce<HW>]:BB:GBAS:TRIGger:SLENgth
[SOURce<HW>]:BB:GBAS:TRIGger:SLUNit
[SOURce<HW>]:BB:GBAS:TRIGger:SOURce
[SOURce<HW>]:BB:GBAS:[TRIGger]:SEQuence
- class TriggerCls[source]
Trigger commands group definition. 22 total commands, 6 Subgroups, 5 group commands
- get_rmode() RsSmw.enums.TrigRunMode [source]
# SCPI: [SOURce<HW>]:BB:GBAS:TRIGger:RMODe value: enums.TrigRunMode = driver.source.bb.gbas.trigger.get_rmode()
Queries the status of signal generation.
- return
rmode: STOP| RUN
- get_sequence() RsSmw.enums.DmTrigMode [source]
# SCPI: [SOURce<HW>]:BB:GBAS:[TRIGger]:SEQuence value: enums.DmTrigMode = driver.source.bb.gbas.trigger.get_sequence()
Selects the trigger mode.
- return
sequence: AUTO| RETRigger| AAUTo| ARETrigger| SINGle
- get_sl_unit() RsSmw.enums.UnitSlB [source]
# SCPI: [SOURce<HW>]:BB:GBAS:TRIGger:SLUNit value: enums.UnitSlB = driver.source.bb.gbas.trigger.get_sl_unit()
Sets the units the trigger sequence length is expressed in.
- return
sl_unit: SEQuence| SAMPle
- get_slength() int [source]
# SCPI: [SOURce<HW>]:BB:GBAS:TRIGger:SLENgth value: int = driver.source.bb.gbas.trigger.get_slength()
Defines the signal sequence length.
- return
slength: integer Range: 1 to 4294967295
- get_source() RsSmw.enums.TriggerSourceC [source]
# SCPI: [SOURce<HW>]:BB:GBAS:TRIGger:SOURce value: enums.TriggerSourceC = driver.source.bb.gbas.trigger.get_source() INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are: - Internal triggering by a command (INTernal) - External trigger signal via one of the local or global connectors Table Header: - EGT1|EGT2: External global trigger - EGC1|EGC2: External global clock - ELTRigger: External local trigger - ELCLock: External local clock - Internal triggering by a signal from the other basebands (INTA|INTB) - OBASeband|BEXTernal|EXTernal: Setting only Provided only for backward
compatibility with other Rohde & Schwarz signal generators. The R&S SMW accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
- return
source: INTernal| EGT1| EXTernal| EGC1 | INTB| OBASeband| ELTRigger| EGT2| EGC2| INTA| ELCLock| BEXTernal
- set_sequence(sequence: RsSmw.enums.DmTrigMode) None [source]
# SCPI: [SOURce<HW>]:BB:GBAS:[TRIGger]:SEQuence driver.source.bb.gbas.trigger.set_sequence(sequence = enums.DmTrigMode.AAUTo)
Selects the trigger mode.
- param sequence
AUTO| RETRigger| AAUTo| ARETrigger| SINGle
- set_sl_unit(sl_unit: RsSmw.enums.UnitSlB) None [source]
# SCPI: [SOURce<HW>]:BB:GBAS:TRIGger:SLUNit driver.source.bb.gbas.trigger.set_sl_unit(sl_unit = enums.UnitSlB.SAMPle)
Sets the units the trigger sequence length is expressed in.
- param sl_unit
SEQuence| SAMPle
- set_slength(slength: int) None [source]
# SCPI: [SOURce<HW>]:BB:GBAS:TRIGger:SLENgth driver.source.bb.gbas.trigger.set_slength(slength = 1)
Defines the signal sequence length.
- param slength
integer Range: 1 to 4294967295
- set_source(source: RsSmw.enums.TriggerSourceC) None [source]
# SCPI: [SOURce<HW>]:BB:GBAS:TRIGger:SOURce driver.source.bb.gbas.trigger.set_source(source = enums.TriggerSourceC.BBSY) INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are: - Internal triggering by a command (INTernal) - External trigger signal via one of the local or global connectors Table Header: - EGT1|EGT2: External global trigger - EGC1|EGC2: External global clock - ELTRigger: External local trigger - ELCLock: External local clock - Internal triggering by a signal from the other basebands (INTA|INTB) - OBASeband|BEXTernal|EXTernal: Setting only Provided only for backward
compatibility with other Rohde & Schwarz signal generators. The R&S SMW accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
- param source
INTernal| EGT1| EXTernal| EGC1 | INTB| OBASeband| ELTRigger| EGT2| EGC2| INTA| ELCLock| BEXTernal
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.source.bb.gbas.trigger.clone()
Subgroups