Source:Power:Level:Immediate#
SCPI Commands
- [SOURce<HW>]:POWer:[LEVel]:[IMMediate]:OFFSet
- [SOURce<HW>]:POWer:[LEVel]:[IMMediate]:RCL
- [SOURce<HW>]:POWer:[LEVel]:[IMMediate]:REFLevel
- [SOURce<HW>]:POWer:[LEVel]:[IMMediate]:[AMPLitude]
Direct SCPI Members
- double Offset#
// SCPI: [SOURce<HW>]:POWer:[LEVel]:[IMMediate]:OFFSet double value = driver.Source.Power.Level.Immediate.Offset; driver.Source.Power.Level.Immediate.Offset = 1.0;Sets the level offset of a downstream instrument. The level at the RF output is not changed. To query the resulting level, as it is at the output of the downstream instrument, use the command method RsSmw.Source.Power.Level.Immediate.Amplitude. See “Displayed RF frequency and level values with downstream instruments”. Note: The level offset also affects the RF level sweep.
offset: float
- InclExclEnum Recall#
// SCPI: [SOURce<HW>]:POWer:[LEVel]:[IMMediate]:RCL InclExclEnum value = driver.Source.Power.Level.Immediate.Recall; driver.Source.Power.Level.Immediate.Recall = InclExclEnum.EXCLude;Determines whether the current level is retained or if the stored level setting is adopted when an instrument configuration is loaded. The setting is valid for both paths. If a suffix is specified, it is ignored.
rcl: INCLude | EXCLude
INCLude: Takes the current level when an instrument configuration is loaded.
EXCLude: Retains the current level when an instrument configuration is loaded.
- double RefLevel#
// SCPI: [SOURce<HW>]:POWer:[LEVel]:[IMMediate]:REFLevel double value = driver.Source.Power.Level.Immediate.RefLevel; driver.Source.Power.Level.Immediate.RefLevel = 1.0;Queries the reference level of the user correction. The reference level is the sum of the amplitude and the level offset, set with the commands .
referenceLevel: float
- double Amplitude#
// SCPI: [SOURce<HW>]:POWer:[LEVel]:[IMMediate]:[AMPLitude] double value = driver.Source.Power.Level.Immediate.Amplitude; driver.Source.Power.Level.Immediate.Amplitude = 1.0;Sets the RF level applied to the DUT. To activate the RF output use command method RsSmw.Output.State.Value (RF On/RF Off) . The following applies POWer = RF output level + OFFSet, where:
POWer is the values set with method RsSmw.Source.Power.Level.Immediate.Amplitude
RF output level is set with method RsSmw.Source.Power.Power
OFFSet is set with method RsSmw.Source.Power.Level.Immediate.Offset
amplitude: The following settings influence the value range: OFFSet set with the command method RsSmw.Source.Power.Level.Immediate.Offset()
Numerical value: Sets the level
UP | DOWN: Varies the level step by step.The level is increased or decreased by the value set with the command [:SOURcehw]:POWer:STEP[:INCRement].