Source:Pm:Deviation#

SCPI Commands

[SOURce<HW>]:PM:DEViation:MODE
[SOURce<HW>]:PM:DEViation:SUM
[SOURce]:PM<CH>:[DEViation]

Direct SCPI Members

ModulationDevModeEnum Mode#
// SCPI: [SOURce<HW>]:PM:DEViation:MODE
ModulationDevModeEnum value = driver.Source.Pm.Deviation.Mode;
driver.Source.Pm.Deviation.Mode = ModulationDevModeEnum.RATio;

Selects the coupling mode. The coupling mode parameter also determines the mode for fixing the total deviation.

pmDevMode: UNCoupled | TOTal | RATio

  • UNCoupled: Does not couple the LF signals.The deviation values of both paths are independent.

  • TOTal: Couples the deviation of both paths.

  • RATio: Couples the deviation ratio of both paths


double Sum#
// SCPI: [SOURce<HW>]:PM:DEViation:SUM
double value = driver.Source.Pm.Deviation.Sum;
driver.Source.Pm.Deviation.Sum = 1.0;

Sets the total deviation of the LF signal when using combined signal sources in phase modulation.

pmDevSum: float


double Get ( )#
double Get ( GeneratorIxRepCap generatorIx )
void Set ( double deviation )#
void Set ( double deviation, GeneratorIxRepCap generatorIx )
// SCPI: [SOURce]:PM<CH>:[DEViation]
// Get:
double value = driver.Source.Pm.Deviation.Get();
double value = driver.Source.Pm.Deviation.Get(GeneratorIxRepCap.Default);
// Set:
driver.Source.Pm.Deviation.Set(1.0, GeneratorIxRepCap.Default);
driver.Source.Pm.Deviation.Set(1.0);

Sets the modulation deviation of the phase modulation in RAD.

deviation The maximal deviation depends on the RF frequency and the selected modulation mode (see the specifications document) .

generatorIx Repeated capability selector

When you do not use any explicit repeated capability selector, the value is taken from its parent group.