Source:Bb:Wlnn:Trigger#
SCPI Commands
- [SOURce<HW>]:BB:WLNN:TRIGger:RMODe
- [SOURce<HW>]:BB:WLNN:TRIGger:SLENgth
- [SOURce<HW>]:BB:WLNN:TRIGger:SLUNit
- [SOURce<HW>]:BB:WLNN:TRIGger:SOURce
- [SOURce<HW>]:BB:WLNN:[TRIGger]:SEQuence
Cloning the Group
// Create a clone of the original group, that exists independently
var trigger2 = driver.Source.Bb.Wlnn.Trigger.Clone();
Direct SCPI Members
- TrigRunModeEnum Rmode#
// SCPI: [SOURce<HW>]:BB:WLNN:TRIGger:RMODe TrigRunModeEnum value = driver.Source.Bb.Wlnn.Trigger.Rmode;The command queries the current status of signal generation for all trigger modes with IEEE 802.11 WLAN modulation on.
rmode: STOP | RUN
STOP: The signal is not generated. A trigger event did not occur in the triggered modes, or signal generation was stopped by the command :SOURce1:BB:WLNN:TRIGger:ARM:EXECute (armed trigger modes only) .
RUN: The signal is generated. A trigger event occurred in the triggered mode.
- int Slength#
// SCPI: [SOURce<HW>]:BB:WLNN:TRIGger:SLENgth int value = driver.Source.Bb.Wlnn.Trigger.Slength; driver.Source.Bb.Wlnn.Trigger.Slength = 1;The command defines the length of the signal sequence to be output in the Single trigger mode (method RsSmw.Source.Bb.Wlnn.Trigger.Sequence is set to SING) . The input is made in terms of samples. It is possible to output deliberately just part of the frame, an exact sequence of the frame, or a defined number of repetitions of the frame.
slength: integer
- UnitSlBenum SlUnit#
// SCPI: [SOURce<HW>]:BB:WLNN:TRIGger:SLUNit UnitSlBenum value = driver.Source.Bb.Wlnn.Trigger.SlUnit; driver.Source.Bb.Wlnn.Trigger.SlUnit = UnitSlBenum.SAMPle;Defines the unit for the entry of the length of the signal sequence (method RsSmw.Source.Bb.Wlnn.Trigger.Slength) to be output in the single trigger mode (method RsSmw.Source.Bb.Wlnn.Trigger.Sequence is set to SINGle) .
slUnit: SEQuence | SAMPle
SEQuence: Unit Sequence Length. A single sequence is generated after a trigger event.
SAMPle: Unit Sample. A single sample is generated after a trigger event.
- TrigSourEnum Source#
// SCPI: [SOURce<HW>]:BB:WLNN:TRIGger:SOURce TrigSourEnum value = driver.Source.Bb.Wlnn.Trigger.Source; driver.Source.Bb.Wlnn.Trigger.Source = TrigSourEnum.BBSY;Selects the trigger signal source and determines the way the triggering is executed. Provided are the following trigger sources:
INTernal: Internal manual triggering of the instrument
INTA | INTB: Internal triggering by a signal from the other basebands
External trigger signal via one of the local or global connectors:
EGT1 | EGT2: External global trigger
EGC1 | EGC2: External global clock
ELTRigger: External local trigger
ELCLock: External local clock
For secondary instruments (SCONfiguration:MULTiinstrument:MODE SEC) , triggering via the external baseband synchronization signal of the primary instrument: SOURce1:BB:ARB:TRIGger:SOURce BBSY
OBASeband | BEXTernal | EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMW200A accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
source: INTB | INTernal | OBASeband | EGT1 | EGT2 | EGC1 | EGC2 | ELTRigger | INTA | ELCLock | BEXTernal | EXTernal | BBSY
- DmTrigModeEnum Sequence#
// SCPI: [SOURce<HW>]:BB:WLNN:[TRIGger]:SEQuence DmTrigModeEnum value = driver.Source.Bb.Wlnn.Trigger.Sequence; driver.Source.Bb.Wlnn.Trigger.Sequence = DmTrigModeEnum.AAUTo;Selects the trigger mode:
AUTO = auto
RETRigger = retrigger
AAUTo = armed auto
ARETrigger = armed retrigger
SINGle = single
sequence: AUTO | RETRigger | AAUTo | ARETrigger | SINGle
Subgroups