Source:Bb:V5G:Trigger#

SCPI Commands

[SOURce<HW>]:BB:V5G:TRIGger:RMODe
[SOURce<HW>]:BB:V5G:TRIGger:SLENgth
[SOURce<HW>]:BB:V5G:TRIGger:SLUNit
[SOURce<HW>]:BB:V5G:TRIGger:SOURce
[SOURce<HW>]:BB:V5G:[TRIGger]:SEQuence

Cloning the Group

// Create a clone of the original group, that exists independently
var trigger2 = driver.Source.Bb.V5G.Trigger.Clone();

Direct SCPI Members

TrigRunModeEnum Rmode#
// SCPI: [SOURce<HW>]:BB:V5G:TRIGger:RMODe
TrigRunModeEnum value = driver.Source.Bb.V5G.Trigger.Rmode;

Queries the signal generation status.

trigRunMode: STOP | RUN


int Slength#
// SCPI: [SOURce<HW>]:BB:V5G:TRIGger:SLENgth
int value = driver.Source.Bb.V5G.Trigger.Slength;
driver.Source.Bb.V5G.Trigger.Slength = 1;

Defines the length of the signal sequence that is output in the SINGle trigger mode.

trigSeqLen: integer


UnitEnum SlUnit#
// SCPI: [SOURce<HW>]:BB:V5G:TRIGger:SLUNit
UnitEnum value = driver.Source.Bb.V5G.Trigger.SlUnit;
driver.Source.Bb.V5G.Trigger.SlUnit = UnitEnum.FRAMe;

Defines the unit for the entry of the signal sequence length, generated after the trigger event.

seqLenUnit: SEQuence | FRAMe | SUBFrame | SLOT | SAMPle

  • SEQuence: Single sequence.

  • FRAMe: Single frame

  • SUBFrame: Single subframe.

  • SLOT: Single slot

  • SAMPle: Selected number of samples.


TrigSourEnum Source#
// SCPI: [SOURce<HW>]:BB:V5G:TRIGger:SOURce
TrigSourEnum value = driver.Source.Bb.V5G.Trigger.Source;
driver.Source.Bb.V5G.Trigger.Source = TrigSourEnum.BBSY;

Selects the trigger signal source and determines the way the triggering is executed. Provided are:

  • Internal triggering by a command (INTernal)

  • External trigger signal via one of the local or global connectors

    • EGT1 | EGT2: External global trigger

    • EGC1 | EGC2: External global clock

    • ELTRigger: External local trigger

    • ELCLock: External local clock

  • Internal triggering by a signal from the other basebands (INTA | INTB)

  • OBASeband | BEXTernal | EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMW accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)

trigSour: INTB | INTernal | OBASeband | EGT1 | EGT2 | EGC1 | EGC2 | ELTRigger | INTA | ELCLock | BEXTernal | EXTernal


DmTrigModeEnum Sequence#
// SCPI: [SOURce<HW>]:BB:V5G:[TRIGger]:SEQuence
DmTrigModeEnum value = driver.Source.Bb.V5G.Trigger.Sequence;
driver.Source.Bb.V5G.Trigger.Sequence = DmTrigModeEnum.AAUTo;

Selects the trigger mode:

  • AUTO = auto

  • RETRigger = retrigger

  • AAUTo = armed auto

  • ARETrigger = armed retrigger

  • SINGle = single

trigMode: AUTO | RETRigger | AAUTo | ARETrigger | SINGle


Subgroups