Source:Bb:Tetra:Trigger#

SCPI Commands

[SOURce<HW>]:BB:TETRa:TRIGger:RMODe
[SOURce<HW>]:BB:TETRa:TRIGger:SEQuence
[SOURce<HW>]:BB:TETRa:TRIGger:SLENgth
[SOURce<HW>]:BB:TETRa:TRIGger:SLUNit
[SOURce<HW>]:BB:TETRa:TRIGger:SOURce

Cloning the Group

// Create a clone of the original group, that exists independently
var trigger2 = driver.Source.Bb.Tetra.Trigger.Clone();

Direct SCPI Members

TrigRunModeEnum Rmode#
// SCPI: [SOURce<HW>]:BB:TETRa:TRIGger:RMODe
TrigRunModeEnum value = driver.Source.Bb.Tetra.Trigger.Rmode;
driver.Source.Bb.Tetra.Trigger.Rmode = TrigRunModeEnum.RUN;

Queries the status of signal generation for all trigger modes.

rmode: STOP | RUN


DmTrigModeEnum Sequence#
// SCPI: [SOURce<HW>]:BB:TETRa:TRIGger:SEQuence
DmTrigModeEnum value = driver.Source.Bb.Tetra.Trigger.Sequence;
driver.Source.Bb.Tetra.Trigger.Sequence = DmTrigModeEnum.AAUTo;

Selects the trigger mode:

  • AUTO = auto

  • RETRigger = retrigger

  • AAUTo = armed auto

  • ARETrigger = armed retrigger

  • SINGle = single

sequence: AUTO | RETRigger | AAUTo | ARETrigger | SINGle


int Slength#
// SCPI: [SOURce<HW>]:BB:TETRa:TRIGger:SLENgth
int value = driver.Source.Bb.Tetra.Trigger.Slength;
driver.Source.Bb.Tetra.Trigger.Slength = 1;

Defines the length of the signal sequence that is output in the SINGle trigger mode.

slength: integer


UnitSlTetraEnum SlUnit#
// SCPI: [SOURce<HW>]:BB:TETRa:TRIGger:SLUNit
UnitSlTetraEnum value = driver.Source.Bb.Tetra.Trigger.SlUnit;
driver.Source.Bb.Tetra.Trigger.SlUnit = UnitSlTetraEnum.MFRame;

Defines the unit of the signal sequence length that is output in the SINGle trigger mode.

slUnit: SEQuence | MFRame


TrigSourEnum Source#
// SCPI: [SOURce<HW>]:BB:TETRa:TRIGger:SOURce
TrigSourEnum value = driver.Source.Bb.Tetra.Trigger.Source;
driver.Source.Bb.Tetra.Trigger.Source = TrigSourEnum.BBSY;

Selects the trigger signal source and determines the way the triggering is executed. Provided are:

  • Internal triggering by a command (INTernal)

  • External trigger signal via one of the local or global connectors

    • EGT1 | EGT2: External global trigger

    • EGC1 | EGC2: External global clock

    • ELTRigger: External local trigger

    • ELCLock: External local clock

  • Internal triggering by a signal from the other basebands (INTA | INTB)

  • OBASeband | BEXTernal | EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMW accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)

source: INTB | INTernal | OBASeband | EGT1 | EGT2 | EGC1 | EGC2 | ELTRigger | INTA | ELCLock | BEXTernal | EXTernal