Source:Bb:Measurement:Power#
SCPI Commands
- [SOURce]:BB:MEASurement:POWer:ABORt
- [SOURce]:BB:MEASurement:POWer:ACQuisition
- [SOURce]:BB:MEASurement:POWer:DELete
- [SOURce]:BB:MEASurement:POWer:DURation
- [SOURce]:BB:MEASurement:POWer:GSOurce
- [SOURce]:BB:MEASurement:POWer:INDex
- [SOURce]:BB:MEASurement:POWer:OUTPut
- [SOURce]:BB:MEASurement:POWer:PEAK
- [SOURce]:BB:MEASurement:POWer:PROGress
- [SOURce]:BB:MEASurement:POWer:RMODe
- [SOURce]:BB:MEASurement:POWer:RMS
- [SOURce]:BB:MEASurement:POWer:RSTate
- [SOURce]:BB:MEASurement:POWer:SOURce
Cloning the Group
// Create a clone of the original group, that exists independently
var power2 = driver.Source.Bb.Measurement.Power.Clone();
Direct SCPI Members
- void Abort ( )#
- void AbortAndWait ( )#
- void AbortAndWait ( int opcTimeoutMs )
// SCPI: [SOURce]:BB:MEASurement:POWer:ABORt driver.Source.Bb.Measurement.Power.Abort(); driver.Source.Bb.Measurement.Power.AbortAndWait(); driver.Source.Bb.Measurement.Power.AbortAndWait(1000);Stops the current measurement.
AbortAndWait is the same as Abort, but waits for the operation to complete. The optional entered opcTimeoutMs is only valid for this call. If you omit the opcTimeoutMs, the method uses the settable value
RsSmw.Utilities.OpcTimeout.
- BbMeasPowAcqEnum Acquisition#
// SCPI: [SOURce]:BB:MEASurement:POWer:ACQuisition BbMeasPowAcqEnum value = driver.Source.Bb.Measurement.Power.Acquisition; driver.Source.Bb.Measurement.Power.Acquisition = BbMeasPowAcqEnum.CONTinuous;Sets the acquisition method.
acquistion: NOMinal | CONTinuous | GATed | MGATed
- void Delete ( )#
- void DeleteAndWait ( )#
- void DeleteAndWait ( int opcTimeoutMs )
// SCPI: [SOURce]:BB:MEASurement:POWer:DELete driver.Source.Bb.Measurement.Power.Delete(); driver.Source.Bb.Measurement.Power.DeleteAndWait(); driver.Source.Bb.Measurement.Power.DeleteAndWait(1000);Removes the selected measurement from the list.
DeleteAndWait is the same as Delete, but waits for the operation to complete. The optional entered opcTimeoutMs is only valid for this call. If you omit the opcTimeoutMs, the method uses the settable value
RsSmw.Utilities.OpcTimeout.
- double Duration#
// SCPI: [SOURce]:BB:MEASurement:POWer:DURation double value = driver.Source.Bb.Measurement.Power.Duration; driver.Source.Bb.Measurement.Power.Duration = 1.0;Sets the measurement’s time of a single measurement.
duration: float
- BbMeasPowGateSourEnum Gsource#
// SCPI: [SOURce]:BB:MEASurement:POWer:GSOurce BbMeasPowGateSourEnum value = driver.Source.Bb.Measurement.Power.Gsource; driver.Source.Bb.Measurement.Power.Gsource = BbMeasPowGateSourEnum.MARK1;Determines the marker signal defining the signal part to be evaluated. The available values depend on the selected acquisition (method RsSmw.Source.Bb.Measurement.Power.Acquisition) .
gateSource: NONE | MARK1 | MARK2 | MARK3 | MGATed
NONE: Default value for nominal and continuous acquisition.
MARK1 | MARK2 | MARK3: Marker signal as defined in the baseband
MGATed: Reserved for multi gated acquisition
- int Index#
// SCPI: [SOURce]:BB:MEASurement:POWer:INDex int value = driver.Source.Bb.Measurement.Power.Index; driver.Source.Bb.Measurement.Power.Index = 1;Selects the measurement index the subsequent settings apply to, for example changing, starting or removing form the list of measurements.
measIndex: integer
- BbMeasPowOutpEnum Output#
// SCPI: [SOURce]:BB:MEASurement:POWer:OUTPut BbMeasPowOutpEnum value = driver.Source.Bb.Measurement.Power.Output; driver.Source.Bb.Measurement.Power.Output = BbMeasPowOutpEnum.BBMM1;Defines the output point the measurement are performed at.
output: RFA | RFB | IQOUT1 | IQOUT2 | BBMM1 | BBMM2
- List<double>Peak#
// SCPI: [SOURce]:BB:MEASurement:POWer:PEAK List<double> value = driver.Source.Bb.Measurement.Power.Peak;Queries the peak power of the baseband signal at the measurement point determined with the command method RsSmw.Source.Bb.Measurement.Power.Output.
peakPower: Returns the peak power of the measured signal or if a multi-gated acquisition is used, a string of measured values with one value per performed submeasurement
- double Progress#
// SCPI: [SOURce]:BB:MEASurement:POWer:PROGress double value = driver.Source.Bb.Measurement.Power.Progress;Queries the status of the initiated measurement. The query returns a value that indicates the task progress in percent.
progress: float
- BlerTrigModeEnum Rmode#
// SCPI: [SOURce]:BB:MEASurement:POWer:RMODe BlerTrigModeEnum value = driver.Source.Bb.Measurement.Power.Rmode; driver.Source.Bb.Measurement.Power.Rmode = BlerTrigModeEnum.AUTO;Determines whether a single or a continuous measurement is executed.
runMode: SINGle | AUTO
- List<double>Rms#
// SCPI: [SOURce]:BB:MEASurement:POWer:RMS List<double> value = driver.Source.Bb.Measurement.Power.Rms;Queries the RMS power of the baseband signal at the measurement point determined with the command method RsSmw.Source.Bb.Measurement.Power.Output.
rmsPower: Returns the power of the measured signal or if a multi-gated acquisition is used, a string of measured values with one value per performed submeasurement
- bool Rstate#
// SCPI: [SOURce]:BB:MEASurement:POWer:RSTate bool value = driver.Source.Bb.Measurement.Power.Rstate;Queries the state (running/stopped) of the current measurement.
runState: 1 | ON | 0| OFF
- BbMeasPowSourEnum Source#
// SCPI: [SOURce]:BB:MEASurement:POWer:SOURce BbMeasPowSourEnum value = driver.Source.Bb.Measurement.Power.Source; driver.Source.Bb.Measurement.Power.Source = BbMeasPowSourEnum.AWGNA;Defines the measurement signal source.
source: BBA | BBB | BBC | BBD | BBINA | BBINB | FADINPA | FADINPB | FADINPC | FADINPD | FADOUTA | FADOUTB | FADOUTC | FADOUTD | AWGNA | AWGNB | AWGNC | AWGND | STREAMA | STREAMB | STREAMC | STREAMD
Subgroups