Source:Bb:Mccw:Trigger#
SCPI Commands
- [SOURce<HW>]:BB:MCCW:TRIGger:RMODe
- [SOURce<HW>]:BB:MCCW:TRIGger:SLENgth
- [SOURce<HW>]:BB:MCCW:TRIGger:SOURce
- [SOURce<HW>]:BB:MCCW:[TRIGger]:SEQuence
Cloning the Group
// Create a clone of the original group, that exists independently
var trigger2 = driver.Source.Bb.Mccw.Trigger.Clone();
Direct SCPI Members
- TrigRunModeEnum Rmode#
// SCPI: [SOURce<HW>]:BB:MCCW:TRIGger:RMODe TrigRunModeEnum value = driver.Source.Bb.Mccw.Trigger.Rmode;Queries the status of signal generation for all trigger mode, if multi-carrier CW generation is on.
rmode: STOP | RUN
- int Slength#
// SCPI: [SOURce<HW>]:BB:MCCW:TRIGger:SLENgth int value = driver.Source.Bb.Mccw.Trigger.Slength;Defines the length of the signal sequence to be output in the Single trigger mode.
slength: integer
- TrigSourEnum Source#
// SCPI: [SOURce<HW>]:BB:MCCW:TRIGger:SOURce TrigSourEnum value = driver.Source.Bb.Mccw.Trigger.Source;Selects the trigger signal source and determines the way the triggering is executed. Provided are the following trigger sources:
INTernal: Internal manual triggering of the instrument
INTA | INTB: Internal triggering by a signal from the other basebands
External trigger signal via one of the local or global connectors:
EGT1 | EGT2: External global trigger
EGC1 | EGC2: External global clock
ELTRigger: External local trigger
ELCLock: External local clock
For secondary instruments (SCONfiguration:MULTiinstrument:MODE SEC) , triggering via the external baseband synchronization signal of the primary instrument: SOURce1:BB:ARB:TRIGger:SOURce BBSY
OBASeband | BEXTernal | EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMW200A accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
source: INTB | INTernal | OBASeband | EGT1 | EGT2 | EGC1 | EGC2 | ELTRigger | INTA | ELCLock | BEXTernal | EXTernal | BBSY
- DmTrigModeEnum Sequence#
// SCPI: [SOURce<HW>]:BB:MCCW:[TRIGger]:SEQuence DmTrigModeEnum value = driver.Source.Bb.Mccw.Trigger.Sequence;Selects the trigger mode. See also “About trigger modes”.
sequence: AUTO | RETRigger | AAUTo | ARETrigger | SINGle
Subgroups