Source:Bb:Huwb:Filter:Parameter#
SCPI Commands
- [SOURce<HW>]:BB:HUWB:FILTer:PARameter:APCo25
- [SOURce<HW>]:BB:HUWB:FILTer:PARameter:GAUSs
- [SOURce<HW>]:BB:HUWB:FILTer:PARameter:LPASs
- [SOURce<HW>]:BB:HUWB:FILTer:PARameter:LPASsevm
- [SOURce<HW>]:BB:HUWB:FILTer:PARameter:PGAuss
- [SOURce<HW>]:BB:HUWB:FILTer:PARameter:RCOSine
- [SOURce<HW>]:BB:HUWB:FILTer:PARameter:SPHase
- [SOURce<HW>]:BB:HUWB:FILTer:PARameter:USER
Cloning the Group
// Create a clone of the original group, that exists independently
var parameter2 = driver.Source.Bb.Huwb.Filter.Parameter.Clone();
Direct SCPI Members
- double Apco25#
// SCPI: [SOURce<HW>]:BB:HUWB:FILTer:PARameter:APCo25 double value = driver.Source.Bb.Huwb.Filter.Parameter.Apco25; driver.Source.Bb.Huwb.Filter.Parameter.Apco25 = 1.0;Sets the filter parameter. Filter type / Parameter / Parameter name / Min / Max / Increment / Default
APCO25 / Rolloff factor / <Apco25> / 0.05 / 0.99 / 0.01 / 0.2
COSine / Rolloff factor / <Cosine> / 0 / 1 / 0.01 / 0.1
GAUSs / BxT / <Gauss> / 0.15 / 2.5 / 0.01 / 0.5
LPASs / Cutoff frequency / <LPass> / 0.02 / 2 / 0.01 / 0.34
LPASSEVM / Cutoff frequency / <CutoffFrequency> / 0.05 / 2 / 0.01 / 0.29
PGAuss / BxT / <PGauss> / 0.15 / 2.5 / 0.01 / 0.5
RCOSine / Rolloff factor / <RCosine> / 0 / 1 / 0.01 / 0.22
SPHase / BxT / <SPhase> / 0.15 / 2.5 / 0.01 / 2
- double Gauss#
// SCPI: [SOURce<HW>]:BB:HUWB:FILTer:PARameter:GAUSs double value = driver.Source.Bb.Huwb.Filter.Parameter.Gauss; driver.Source.Bb.Huwb.Filter.Parameter.Gauss = 1.0;Sets the filter parameter. Filter type / Parameter / Parameter name / Min / Max / Increment / Default
APCO25 / Rolloff factor / <Apco25> / 0.05 / 0.99 / 0.01 / 0.2
COSine / Rolloff factor / <Cosine> / 0 / 1 / 0.01 / 0.1
GAUSs / BxT / <Gauss> / 0.15 / 2.5 / 0.01 / 0.5
LPASs / Cutoff frequency / <LPass> / 0.02 / 2 / 0.01 / 0.34
LPASSEVM / Cutoff frequency / <CutoffFrequency> / 0.05 / 2 / 0.01 / 0.29
PGAuss / BxT / <PGauss> / 0.15 / 2.5 / 0.01 / 0.5
RCOSine / Rolloff factor / <RCosine> / 0 / 1 / 0.01 / 0.22
SPHase / BxT / <SPhase> / 0.15 / 2.5 / 0.01 / 2
- double Lpass#
// SCPI: [SOURce<HW>]:BB:HUWB:FILTer:PARameter:LPASs double value = driver.Source.Bb.Huwb.Filter.Parameter.Lpass; driver.Source.Bb.Huwb.Filter.Parameter.Lpass = 1.0;Sets the filter parameter. Filter type / Parameter / Parameter name / Min / Max / Increment / Default
APCO25 / Rolloff factor / <Apco25> / 0.05 / 0.99 / 0.01 / 0.2
COSine / Rolloff factor / <Cosine> / 0 / 1 / 0.01 / 0.1
GAUSs / BxT / <Gauss> / 0.15 / 2.5 / 0.01 / 0.5
LPASs / Cutoff frequency / <LPass> / 0.02 / 2 / 0.01 / 0.34
LPASSEVM / Cutoff frequency / <CutoffFrequency> / 0.05 / 2 / 0.01 / 0.29
PGAuss / BxT / <PGauss> / 0.15 / 2.5 / 0.01 / 0.5
RCOSine / Rolloff factor / <RCosine> / 0 / 1 / 0.01 / 0.22
SPHase / BxT / <SPhase> / 0.15 / 2.5 / 0.01 / 2
- double LpassEvm#
// SCPI: [SOURce<HW>]:BB:HUWB:FILTer:PARameter:LPASsevm double value = driver.Source.Bb.Huwb.Filter.Parameter.LpassEvm; driver.Source.Bb.Huwb.Filter.Parameter.LpassEvm = 1.0;Sets the filter parameter. Filter type / Parameter / Parameter name / Min / Max / Increment / Default
APCO25 / Rolloff factor / <Apco25> / 0.05 / 0.99 / 0.01 / 0.2
COSine / Rolloff factor / <Cosine> / 0 / 1 / 0.01 / 0.1
GAUSs / BxT / <Gauss> / 0.15 / 2.5 / 0.01 / 0.5
LPASs / Cutoff frequency / <LPass> / 0.02 / 2 / 0.01 / 0.34
LPASSEVM / Cutoff frequency / <CutoffFrequency> / 0.05 / 2 / 0.01 / 0.29
PGAuss / BxT / <PGauss> / 0.15 / 2.5 / 0.01 / 0.5
RCOSine / Rolloff factor / <RCosine> / 0 / 1 / 0.01 / 0.22
SPHase / BxT / <SPhase> / 0.15 / 2.5 / 0.01 / 2
- double Pgauss#
// SCPI: [SOURce<HW>]:BB:HUWB:FILTer:PARameter:PGAuss double value = driver.Source.Bb.Huwb.Filter.Parameter.Pgauss; driver.Source.Bb.Huwb.Filter.Parameter.Pgauss = 1.0;Sets the filter parameter. Filter type / Parameter / Parameter name / Min / Max / Increment / Default
APCO25 / Rolloff factor / <Apco25> / 0.05 / 0.99 / 0.01 / 0.2
COSine / Rolloff factor / <Cosine> / 0 / 1 / 0.01 / 0.1
GAUSs / BxT / <Gauss> / 0.15 / 2.5 / 0.01 / 0.5
LPASs / Cutoff frequency / <LPass> / 0.02 / 2 / 0.01 / 0.34
LPASSEVM / Cutoff frequency / <CutoffFrequency> / 0.05 / 2 / 0.01 / 0.29
PGAuss / BxT / <PGauss> / 0.15 / 2.5 / 0.01 / 0.5
RCOSine / Rolloff factor / <RCosine> / 0 / 1 / 0.01 / 0.22
SPHase / BxT / <SPhase> / 0.15 / 2.5 / 0.01 / 2
- double Rcosine#
// SCPI: [SOURce<HW>]:BB:HUWB:FILTer:PARameter:RCOSine double value = driver.Source.Bb.Huwb.Filter.Parameter.Rcosine; driver.Source.Bb.Huwb.Filter.Parameter.Rcosine = 1.0;Sets the filter parameter. Filter type / Parameter / Parameter name / Min / Max / Increment / Default
APCO25 / Rolloff factor / <Apco25> / 0.05 / 0.99 / 0.01 / 0.2
COSine / Rolloff factor / <Cosine> / 0 / 1 / 0.01 / 0.1
GAUSs / BxT / <Gauss> / 0.15 / 2.5 / 0.01 / 0.5
LPASs / Cutoff frequency / <LPass> / 0.02 / 2 / 0.01 / 0.34
LPASSEVM / Cutoff frequency / <CutoffFrequency> / 0.05 / 2 / 0.01 / 0.29
PGAuss / BxT / <PGauss> / 0.15 / 2.5 / 0.01 / 0.5
RCOSine / Rolloff factor / <RCosine> / 0 / 1 / 0.01 / 0.22
SPHase / BxT / <SPhase> / 0.15 / 2.5 / 0.01 / 2
- double Sphase#
// SCPI: [SOURce<HW>]:BB:HUWB:FILTer:PARameter:SPHase double value = driver.Source.Bb.Huwb.Filter.Parameter.Sphase; driver.Source.Bb.Huwb.Filter.Parameter.Sphase = 1.0;Sets the filter parameter. Filter type / Parameter / Parameter name / Min / Max / Increment / Default
APCO25 / Rolloff factor / <Apco25> / 0.05 / 0.99 / 0.01 / 0.2
COSine / Rolloff factor / <Cosine> / 0 / 1 / 0.01 / 0.1
GAUSs / BxT / <Gauss> / 0.15 / 2.5 / 0.01 / 0.5
LPASs / Cutoff frequency / <LPass> / 0.02 / 2 / 0.01 / 0.34
LPASSEVM / Cutoff frequency / <CutoffFrequency> / 0.05 / 2 / 0.01 / 0.29
PGAuss / BxT / <PGauss> / 0.15 / 2.5 / 0.01 / 0.5
RCOSine / Rolloff factor / <RCosine> / 0 / 1 / 0.01 / 0.22
SPHase / BxT / <SPhase> / 0.15 / 2.5 / 0.01 / 2
sphase: float
- string User#
// SCPI: [SOURce<HW>]:BB:HUWB:FILTer:PARameter:USER string value = driver.Source.Bb.Huwb.Filter.Parameter.User; driver.Source.Bb.Huwb.Filter.Parameter.User = "abc";Loads the file from the default or the specified directory. Loaded are files with extension vaf or dat. Refer to for general information on file handling in the default and in a specific directory.
filename: string
Subgroups