Source:Bb:Arbitrary:Trigger#
SCPI Commands
- [SOURce<HW>]:BB:ARBitrary:TRIGger:PTIMe
- [SOURce<HW>]:BB:ARBitrary:TRIGger:RMODe
- [SOURce<HW>]:BB:ARBitrary:TRIGger:SLENgth
- [SOURce<HW>]:BB:ARBitrary:TRIGger:SLUNit
- [SOURce<HW>]:BB:ARBitrary:TRIGger:SMODe
- [SOURce<HW>]:BB:ARBitrary:TRIGger:SOURce
- [SOURce<HW>]:BB:ARBitrary:[TRIGger]:SEQuence
Cloning the Group
// Create a clone of the original group, that exists independently
var trigger2 = driver.Source.Bb.Arbitrary.Trigger.Clone();
Direct SCPI Members
- string Ptime#
// SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:PTIMe string value = driver.Source.Bb.Arbitrary.Trigger.Ptime;Queries the internal processing time. The processing time is the elapsed time between the input of the external trigger event and the output of the baseband signal.
arbTrigProcTime: string
- TrigRunModeEnum Rmode#
// SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:RMODe TrigRunModeEnum value = driver.Source.Bb.Arbitrary.Trigger.Rmode;Queries the status of waveform output.
rmode: STOP | RUN
RUN: Outputs the waveform. A trigger event occurred in the triggered mode.
STOP: No waveform output. A trigger event did not occur in the triggered modes, or waveform output was stopped/armed.
- int Slength#
// SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:SLENgth int value = driver.Source.Bb.Arbitrary.Trigger.Slength; driver.Source.Bb.Arbitrary.Trigger.Slength = 1;Sets the length of the signal sequence that is output in the SINGle trigger mode.
slength: The maximum value depends on the selected units method RsSmw.Source.Bb.Arbitrary.Trigger.SlUnit() as follows: SAMPle: Max = 232-1 SEQuence: Max = 1000
- UnitSlBenum SlUnit#
// SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:SLUNit UnitSlBenum value = driver.Source.Bb.Arbitrary.Trigger.SlUnit; driver.Source.Bb.Arbitrary.Trigger.SlUnit = UnitSlBenum.SAMPle;Sets the unit for the entry of the length of the signal sequence to be output in the Single trigger mode.
slUnit: SEQuence | SAMPle
- ArbTrigSegmModeNoEhopEnum Smode#
// SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:SMODe ArbTrigSegmModeNoEhopEnum value = driver.Source.Bb.Arbitrary.Trigger.Smode; driver.Source.Bb.Arbitrary.Trigger.Smode = ArbTrigSegmModeNoEhopEnum.NEXT;Selects the extended trigger mode for multi segment waveforms.
smode: NSEam = Next Segment Seamless
- TrigSourEnum Source#
// SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:SOURce TrigSourEnum value = driver.Source.Bb.Arbitrary.Trigger.Source; driver.Source.Bb.Arbitrary.Trigger.Source = TrigSourEnum.BBSY;Selects the trigger signal source and determines the way the triggering is executed. Provided are the following trigger sources:
INTernal: Internal manual triggering of the instrument
INTA | INTB: Internal triggering by a signal from the other basebands
External trigger signal via one of the local or global connectors:
EGT1 | EGT2: External global trigger
EGC1 | EGC2: External global clock
ELTRigger: External local trigger
ELCLock: External local clock
For secondary instruments (SCONfiguration:MULTiinstrument:MODE SEC) , triggering via the external baseband synchronization signal of the primary instrument: SOURce1:BB:ARB:TRIGger:SOURce BBSY
OBASeband | BEXTernal | EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMW200A accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
source: INTB | INTernal | OBASeband | EGT1 | EGT2 | EGC1 | EGC2 | ELTRigger | INTA | ELCLock | BEXTernal | EXTernal | BBSY
- DmTrigModeEnum Sequence#
// SCPI: [SOURce<HW>]:BB:ARBitrary:[TRIGger]:SEQuence DmTrigModeEnum value = driver.Source.Bb.Arbitrary.Trigger.Sequence; driver.Source.Bb.Arbitrary.Trigger.Sequence = DmTrigModeEnum.AAUTo;Selects the trigger mode:
AUTO = auto
RETRigger = retrigger
AAUTo = armed auto
ARETrigger = armed retrigger
SINGle = single
See also “About trigger modes”.
sequence: AUTO | RETRigger | AAUTo | ARETrigger | SINGle