Source code for RsSmbv.Implementations.Trigger.FpSweep.Source

from ....Internal.Core import Core
from ....Internal.CommandsGroup import CommandsGroup
from ....Internal import Conversions
from .... import enums
from .... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class SourceCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("source", core, parent)

[docs] def set(self, fp_trig_source: enums.SingExtAuto, inputIx=repcap.InputIx.Default) -> None: """ ``TRIGger<HW>:FPSWeep:SOURce`` \n Snippet: ``driver.trigger.fpSweep.source.set(fp_trig_source = enums.SingExtAuto.AUTO, inputIx = repcap.InputIx.Default)`` \n Selects the trigger source for the combined RF frequency / level sweep. The parameter names correspond to the manual control. If needed, see table Table 'Cross-reference between the manual and remote control' for selecting the trigger source with SCPI compliant parameter names. :param fp_trig_source: AUTO | IMMediate | SINGle | BUS | EXTernal | EAUTo AUTO | IMMediate Executes the combined RF sweep automatically. In this free-running mode, the trigger condition is met continuously. I.e. as soon as a sweep is completed, the next one starts immediately. SINGle | BUS Executes one complete sweep cycle triggered by the GPIB commands method ``RsSmbv.source.sweep.combined.execute.set()`` or ``*TRG``. The mode has to be set to [:SOURcehw]:SWEep:COMBined:MODE AUTO. EXTernal An external signal triggers the sweep. EAUTo An external signal triggers the sweep. As soon as one sweep is finished, the next sweep starts. A second trigger event stops the sweep at the current frequency and level value pairs, a third trigger event starts the trigger at the start values, and so on. :param inputIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Trigger') """ param = Conversions.enum_scalar_to_str(fp_trig_source, enums.SingExtAuto) inputIx_cmd_val = self._cmd_group.get_repcap_cmd_value(inputIx, repcap.InputIx) self._core.io.write(f'TRIGger{inputIx_cmd_val}:FPSWeep:SOURce {param}')
# noinspection PyTypeChecker
[docs] def get(self, inputIx=repcap.InputIx.Default) -> enums.SingExtAuto: """ ``TRIGger<HW>:FPSWeep:SOURce`` \n Snippet: ``value: enums.SingExtAuto = driver.trigger.fpSweep.source.get(inputIx = repcap.InputIx.Default)`` \n Selects the trigger source for the combined RF frequency / level sweep. The parameter names correspond to the manual control. If needed, see table Table 'Cross-reference between the manual and remote control' for selecting the trigger source with SCPI compliant parameter names. :param inputIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Trigger') :return: fp_trig_source: AUTO | IMMediate | SINGle | BUS | EXTernal | EAUTo AUTO | IMMediate Executes the combined RF sweep automatically. In this free-running mode, the trigger condition is met continuously. I.e. as soon as a sweep is completed, the next one starts immediately. SINGle | BUS Executes one complete sweep cycle triggered by the GPIB commands method ``RsSmbv.source.sweep.combined.execute.set()`` or ``*TRG``. The mode has to be set to [:SOURcehw]:SWEep:COMBined:MODE AUTO. EXTernal An external signal triggers the sweep. EAUTo An external signal triggers the sweep. As soon as one sweep is finished, the next sweep starts. A second trigger event stops the sweep at the current frequency and level value pairs, a third trigger event starts the trigger at the start values, and so on. """ inputIx_cmd_val = self._cmd_group.get_repcap_cmd_value(inputIx, repcap.InputIx) response = self._core.io.query_str(f'TRIGger{inputIx_cmd_val}:FPSWeep:SOURce?') return Conversions.str_to_scalar_enum(response, enums.SingExtAuto)