[docs] def set(self, signal: enums.OutpConnGlbSignal, userIx=repcap.UserIx.Default) -> None:
"""SCPI: OUTPut<HW>:USER<CH>:SIGNal \n
Snippet: driver.output.user.signal.set(signal = enums.OutpConnGlbSignal.BERCLKOUT, userIx = repcap.UserIx.Default) \n
Sets the control signal that is output at the selected connector. To define the connector direction, use the command
method RsSmbv.Output.User.Direction.set. \n
:param signal: MARKA1| MARKA2| MARKA3| NONE| SYNCOUT| SCLock| LATTenuation| BGATe| HOP| CWMODulation| TRIGgered| MTRigger| LOW| HIGH | BERRESTOUT| BERDATENOUT| BERCLKOUT| BERDATOUT MARKA1|2|3 = Baseband Marker 1/2/3 MTRigger = Manual Trigger, available for USER5 BERRESTOUT|BERDATENOUT|BERCLKOUT|BERDATOUT = BER TestGen Data, Clock, Data Enable and Restart SYNCOUT = Baseband Sync Out SCLock = Symbol Clock LATTenuation = Lev Att BGATA = Burst Gate HOP = HOP CWMODulation = CW/Mod TRIGgered = Triggered MTRigger = Manual Trigger, available for USER5 LOW|HIGH = Always 0/1 NONE = none
:param userIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'User')
"""
param = Conversions.enum_scalar_to_str(signal, enums.OutpConnGlbSignal)
userIx_cmd_val = self._cmd_group.get_repcap_cmd_value(userIx, repcap.UserIx)
self._core.io.write(f'OUTPut<HwInstance>:USER{userIx_cmd_val}:SIGNal {param}')
# noinspection PyTypeChecker
[docs] def get(self, userIx=repcap.UserIx.Default) -> enums.OutpConnGlbSignal:
"""SCPI: OUTPut<HW>:USER<CH>:SIGNal \n
Snippet: value: enums.OutpConnGlbSignal = driver.output.user.signal.get(userIx = repcap.UserIx.Default) \n
Sets the control signal that is output at the selected connector. To define the connector direction, use the command
method RsSmbv.Output.User.Direction.set. \n
:param userIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'User')
:return: signal: MARKA1| MARKA2| MARKA3| NONE| SYNCOUT| SCLock| LATTenuation| BGATe| HOP| CWMODulation| TRIGgered| MTRigger| LOW| HIGH | BERRESTOUT| BERDATENOUT| BERCLKOUT| BERDATOUT MARKA1|2|3 = Baseband Marker 1/2/3 MTRigger = Manual Trigger, available for USER5 BERRESTOUT|BERDATENOUT|BERCLKOUT|BERDATOUT = BER TestGen Data, Clock, Data Enable and Restart SYNCOUT = Baseband Sync Out SCLock = Symbol Clock LATTenuation = Lev Att BGATA = Burst Gate HOP = HOP CWMODulation = CW/Mod TRIGgered = Triggered MTRigger = Manual Trigger, available for USER5 LOW|HIGH = Always 0/1 NONE = none"""
userIx_cmd_val = self._cmd_group.get_repcap_cmd_value(userIx, repcap.UserIx)
response = self._core.io.query_str(f'OUTPut<HwInstance>:USER{userIx_cmd_val}:SIGNal?')