Source code for RsSmbv.Implementations.Output.User.Signal

from ....Internal.Core import Core
from ....Internal.CommandsGroup import CommandsGroup
from ....Internal import Conversions
from .... import enums
from .... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class SignalCls: """Signal commands group definition. 1 total commands, 0 Subgroups, 1 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("signal", core, parent)
[docs] def set(self, signal: enums.OutpConnGlbSignal, userIx=repcap.UserIx.Default) -> None: """SCPI: OUTPut<HW>:USER<CH>:SIGNal \n Snippet: driver.output.user.signal.set(signal = enums.OutpConnGlbSignal.BERCLKOUT, userIx = repcap.UserIx.Default) \n Sets the control signal that is output at the selected connector. To define the connector direction, use the command method RsSmbv.Output.User.Direction.set. \n :param signal: MARKA1| MARKA2| MARKA3| NONE| SYNCOUT| SCLock| LATTenuation| BGATe| HOP| CWMODulation| TRIGgered| MTRigger| LOW| HIGH | BERRESTOUT| BERDATENOUT| BERCLKOUT| BERDATOUT MARKA1|2|3 = Baseband Marker 1/2/3 MTRigger = Manual Trigger, available for USER5 BERRESTOUT|BERDATENOUT|BERCLKOUT|BERDATOUT = BER TestGen Data, Clock, Data Enable and Restart SYNCOUT = Baseband Sync Out SCLock = Symbol Clock LATTenuation = Lev Att BGATA = Burst Gate HOP = HOP CWMODulation = CW/Mod TRIGgered = Triggered MTRigger = Manual Trigger, available for USER5 LOW|HIGH = Always 0/1 NONE = none :param userIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'User') """ param = Conversions.enum_scalar_to_str(signal, enums.OutpConnGlbSignal) userIx_cmd_val = self._cmd_group.get_repcap_cmd_value(userIx, repcap.UserIx) self._core.io.write(f'OUTPut<HwInstance>:USER{userIx_cmd_val}:SIGNal {param}')
# noinspection PyTypeChecker
[docs] def get(self, userIx=repcap.UserIx.Default) -> enums.OutpConnGlbSignal: """SCPI: OUTPut<HW>:USER<CH>:SIGNal \n Snippet: value: enums.OutpConnGlbSignal = driver.output.user.signal.get(userIx = repcap.UserIx.Default) \n Sets the control signal that is output at the selected connector. To define the connector direction, use the command method RsSmbv.Output.User.Direction.set. \n :param userIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'User') :return: signal: MARKA1| MARKA2| MARKA3| NONE| SYNCOUT| SCLock| LATTenuation| BGATe| HOP| CWMODulation| TRIGgered| MTRigger| LOW| HIGH | BERRESTOUT| BERDATENOUT| BERCLKOUT| BERDATOUT MARKA1|2|3 = Baseband Marker 1/2/3 MTRigger = Manual Trigger, available for USER5 BERRESTOUT|BERDATENOUT|BERCLKOUT|BERDATOUT = BER TestGen Data, Clock, Data Enable and Restart SYNCOUT = Baseband Sync Out SCLock = Symbol Clock LATTenuation = Lev Att BGATA = Burst Gate HOP = HOP CWMODulation = CW/Mod TRIGgered = Triggered MTRigger = Manual Trigger, available for USER5 LOW|HIGH = Always 0/1 NONE = none""" userIx_cmd_val = self._cmd_group.get_repcap_cmd_value(userIx, repcap.UserIx) response = self._core.io.query_str(f'OUTPut<HwInstance>:USER{userIx_cmd_val}:SIGNal?') return Conversions.str_to_scalar_enum(response, enums.OutpConnGlbSignal)