Source
SCPI Command :
TRIGger<HW>:FSWeep:SOURce
- class SourceCls[source]
Source commands group definition. 2 total commands, 1 Subgroups, 1 group commands
- get(inputIx=InputIx.Default) RsSmbv.enums.SingExtAuto [source]
# SCPI: TRIGger<HW>:FSWeep:SOURce value: enums.SingExtAuto = driver.trigger.freqSweep.source.get(inputIx = repcap.InputIx.Default) INTRO_CMD_HELP: Selects the trigger source for the corresponding sweeps: - FSWeep - RF frequency - LFFSweep - LF frequency - PSWeep - RF level - SWEep - all sweeps
The source names of the parameters correspond to the values provided in manual control of the instrument. They differ from the SCPI-compliant names, but the instrument accepts both variants. Use the SCPI name, if compatibility is an important issue. Find the corresponding SCPI-compliant commands in Cross-reference between the manual and remote control.
- param inputIx
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)
- return
source: AUTO| IMMediate | SINGle| BUS | EXTernal | EAUTo AUTO [IMMediate] Executes a sweep automatically. In this free-running mode, the trigger condition is met continuously. I.e. when a sweep is completed, the next one starts immediately. SINGle [BUS] Executes one complete sweep cycle. The following commands initiate a trigger event: *TRG [:SOURcehw]:SWEep:POWer:EXECute [:SOURcehw]:SWEep[:FREQuency]:EXECute method RsSmbv.Trigger.Sweep.Immediate.set, method RsSmbv.Trigger.Psweep.Immediate.set and method RsSmbv.Trigger.FreqSweep.Immediate.set. Set the sweep mode with the commands: [:SOURcehw]:SWEep:POWer:MODEAUTO|STEP [:SOURcehw]:SWEep[:FREQuency]:MODEAUTO|STEP [:SOURcehw]:LFOutput:SWEep[:FREQuency]:MODEAUTO|STEP In step mode (STEP) , the instrument executes only one step. EXTernal An external signal triggers the sweep. EAUTo An external signal triggers the sweep. When one sweep is finished, the next sweep starts. A second trigger event stops the sweep at the current frequency, a third trigger event starts the trigger at the start frequency, and so on.
- set(source: RsSmbv.enums.SingExtAuto, inputIx=InputIx.Default) None [source]
# SCPI: TRIGger<HW>:FSWeep:SOURce driver.trigger.freqSweep.source.set(source = enums.SingExtAuto.AUTO, inputIx = repcap.InputIx.Default) INTRO_CMD_HELP: Selects the trigger source for the corresponding sweeps: - FSWeep - RF frequency - LFFSweep - LF frequency - PSWeep - RF level - SWEep - all sweeps
The source names of the parameters correspond to the values provided in manual control of the instrument. They differ from the SCPI-compliant names, but the instrument accepts both variants. Use the SCPI name, if compatibility is an important issue. Find the corresponding SCPI-compliant commands in Cross-reference between the manual and remote control.
- param source
AUTO| IMMediate | SINGle| BUS | EXTernal | EAUTo AUTO [IMMediate] Executes a sweep automatically. In this free-running mode, the trigger condition is met continuously. I.e. when a sweep is completed, the next one starts immediately. SINGle [BUS] Executes one complete sweep cycle. The following commands initiate a trigger event: *TRG [:SOURcehw]:SWEep:POWer:EXECute [:SOURcehw]:SWEep[:FREQuency]:EXECute method RsSmbv.Trigger.Sweep.Immediate.set, method RsSmbv.Trigger.Psweep.Immediate.set and method RsSmbv.Trigger.FreqSweep.Immediate.set. Set the sweep mode with the commands: [:SOURcehw]:SWEep:POWer:MODEAUTO|STEP [:SOURcehw]:SWEep[:FREQuency]:MODEAUTO|STEP [:SOURcehw]:LFOutput:SWEep[:FREQuency]:MODEAUTO|STEP In step mode (STEP) , the instrument executes only one step. EXTernal An external signal triggers the sweep. EAUTo An external signal triggers the sweep. When one sweep is finished, the next sweep starts. A second trigger event stops the sweep at the current frequency, a third trigger event starts the trigger at the start frequency, and so on.
- param inputIx
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.trigger.freqSweep.source.clone()
Subgroups