Mshift
SCPI Command :
[SOURce<HW>]:BB:TDSCdma:UP:CELL<ST>:SLOT<CH0>:PRAC:MSG:MSHift
- class MshiftCls[source]
Mshift commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(cell=Cell.Default, slotNull=SlotNull.Default) int [source]
# SCPI: [SOURce<HW>]:BB:TDSCdma:UP:CELL<ST>:SLOT<CH0>:PRAC:MSG:MSHift value: int = driver.source.bb.tdscdma.up.cell.slot.prac.msg.mshift.get(cell = repcap.Cell.Default, slotNull = repcap.SlotNull.Default)
Queries the value of the midamble shift.
- param cell
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cell’)
- param slotNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Slot’)
- return
mshift: integer Range: 0 to 128