Iconnect

SCPI Command :

SCONfiguration:EXTernal:IQOutput<CH>:REMote:ICONnect
class IconnectCls[source]

Iconnect commands group definition. 1 total commands, 0 Subgroups, 1 group commands

set(ipart_instr_name: str, rf_path: str, iqConnector=IqConnector.Default) None[source]
# SCPI: SCONfiguration:EXTernal:IQOutput<CH>:REMote:ICONnect
driver.sconfiguration.external.iqOutput.remote.iconnect.set(ipart_instr_name = 'abc', rf_path = 'abc', iqConnector = repcap.IqConnector.Default)

Selects an external instrument for the selected connector and triggers connection.

param ipart_instr_name

string Instrument alias name, as retrieved with the command method RsSmbv.Sconfiguration.External.Remote.listPy or defined with the command method RsSmbv.Sconfiguration.External.Remote.Add.set.

param rf_path

string Determines the used RF output of the external instrument. For a one-path instrument, the output path is fixed.

param iqConnector

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘IqOutput’)