from .......Internal.Core import Core
from .......Internal.CommandsGroup import CommandsGroup
from .......Internal import Conversions
from ....... import repcap
# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class NmOffsetCls:
"""NmOffset commands group definition. 1 total commands, 0 Subgroups, 1 group commands"""
def __init__(self, core: Core, parent):
self._core = core
self._cmd_group = CommandsGroup("nmOffset", core, parent)
[docs] def set(self, nm_offset: float, probe=repcap.Probe.Default) -> None:
"""SCPI: [SENSe]:PROBe<pb>:SETup:NMOFfset \n
Snippet: driver.applications.k17Mcgd.sense.probe.setup.nmOffset.set(nm_offset = 1.0, probe = repcap.Probe.Default) \n
Sets the N-mode offset. The setting is only available if a modular probe in N-mode is connected to the FSW. The maximum
voltage difference between the positive and negative input terminals is 16 V. If the probe is disconnected, the N-mode
offset of the probe is reset to 0.0 V. Note that if the offset for DM-mode or CM-mode is changed, the offsets for the
P-mode and N-mode are adapted accordingly, and vice versa. For details see 'Using Probes'. \n
:param nm_offset: The voltage offset between the negative input terminal and ground. Unit: V
:param probe: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Probe')
"""
param = Conversions.decimal_value_to_str(nm_offset)
probe_cmd_val = self._cmd_group.get_repcap_cmd_value(probe, repcap.Probe)
self._core.io.write(f'SENSe:PROBe{probe_cmd_val}:SETup:NMOFfset {param}')
[docs] def get(self, probe=repcap.Probe.Default) -> float:
"""SCPI: [SENSe]:PROBe<pb>:SETup:NMOFfset \n
Snippet: value: float = driver.applications.k17Mcgd.sense.probe.setup.nmOffset.get(probe = repcap.Probe.Default) \n
Sets the N-mode offset. The setting is only available if a modular probe in N-mode is connected to the FSW. The maximum
voltage difference between the positive and negative input terminals is 16 V. If the probe is disconnected, the N-mode
offset of the probe is reset to 0.0 V. Note that if the offset for DM-mode or CM-mode is changed, the offsets for the
P-mode and N-mode are adapted accordingly, and vice versa. For details see 'Using Probes'. \n
:param probe: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Probe')
:return: nm_offset: The voltage offset between the negative input terminal and ground. Unit: V"""
probe_cmd_val = self._cmd_group.get_repcap_cmd_value(probe, repcap.Probe)
response = self._core.io.query_str(f'SENSe:PROBe{probe_cmd_val}:SETup:NMOFfset?')
return Conversions.str_to_float(response)