Function

SCPI Command :

[SENSe]:ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STOP:FUNCtion
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(subBlock=SubBlock.Default, rangePy=RangePy.Default, limitIx=LimitIx.Default) FunctionA[source]
# [SENSe]:ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STOP:FUNCtion
value: enums.FunctionA = driver.sense.espectrum.range.limit.relative.stop.function.get(subBlock = repcap.SubBlock.Default, rangePy = repcap.RangePy.Default, limitIx = repcap.LimitIx.Default)

Enables the use of a function when defining the relative limit for a SEM range.

Parameters:
  • subBlock – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Espectrum’)

  • rangePy – optional repeated capability selector. Default value: Ix1 (settable in the interface ‘Range’)

  • limitIx – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Limit’)

Returns:

function: OFF | MAX Defines the function to be used to determine the relative limit line stop value MAX The maximum of the relative and the absolute level is used as the limit stop value. Use the method RsFsw.sense.espectrum.range.limit.relative.stop.set() and method RsFsw.sense.espectrum.range.limit.relative.stop.abs.set() commands to define these values. OFF No function is used, the relative limit line is defined by a fixed relative stop value. Use the method RsFsw.sense.espectrum.range.limit.relative.stop.set() command to define this value.

set(function: FunctionA, subBlock=SubBlock.Default, rangePy=RangePy.Default, limitIx=LimitIx.Default) None[source]
# [SENSe]:ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STOP:FUNCtion
driver.sense.espectrum.range.limit.relative.stop.function.set(function = enums.FunctionA.MAX, subBlock = repcap.SubBlock.Default, rangePy = repcap.RangePy.Default, limitIx = repcap.LimitIx.Default)

Enables the use of a function when defining the relative limit for a SEM range.

Parameters:
  • function – OFF | MAX Defines the function to be used to determine the relative limit line stop value MAX The maximum of the relative and the absolute level is used as the limit stop value. Use the method RsFsw.sense.espectrum.range.limit.relative.stop.set() and method RsFsw.sense.espectrum.range.limit.relative.stop.abs.set() commands to define these values. OFF No function is used, the relative limit line is defined by a fixed relative stop value. Use the method RsFsw.sense.espectrum.range.limit.relative.stop.set() command to define this value.

  • subBlock – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Espectrum’)

  • rangePy – optional repeated capability selector. Default value: Ix1 (settable in the interface ‘Range’)

  • limitIx – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Limit’)