RsFsw

Contents:

  • Revision History
  • Getting Started
  • Enums
  • RepCaps
  • Examples
  • Instrument API
    • Applications
      • IqAnalyzer
      • K10x_Lte
      • K149_Uwb
      • K14x_Nr5G
      • K17_Mcgd
      • K18_AmplifierEt
      • K30_NoiseFigure
      • K40_PhaseNoise
      • K50_Spurious
      • K6_Pulse
      • K60_Transient
      • K7_AnalogDemod
      • K70_Vsa
      • K91_Wlan
      • K9x_11ad
        • Calculate<Window>
          • DeltaMarker<DeltaMarker>
            • Aoff
            • LinkTo
            • Maximum
              • Left
              • Next
              • Peak
              • Right
            • Minimum
            • State
            • Trace
            • X
            • Y
          • Limit<LimitIx>
          • Marker<Marker>
          • Pmeter<PowerMeter>
          • Unit
        • Calibration
        • Configure
        • Display
        • Fetch
        • FormatPy
        • Initiate
        • InputPy
        • Layout
        • MassMemory
        • Output
        • Read
        • Sense
        • System
        • Trace<Window>
        • Trigger
        • Unit
    • Calculate<Window>
    • Calibration
    • Configure
    • Diagnostic
    • Display
    • Fetch<Window>
    • FormatPy
    • HardCopy
    • Initiate
    • InputPy<InputPy>
    • Instrument
    • Layout
    • MassMemory
    • Output<OutputConnector>
    • Read
    • Sense
    • Source
    • Status
    • System
    • Trace<Window>
    • Trigger
    • TriggerInvoke
    • Unit
  • Utilities
  • Logger
  • Events
  • Index
RsFsw
  • Instrument API
  • Applications
  • K9x_11ad
  • Calculate<Window>
  • DeltaMarker<DeltaMarker>
  • Maximum
  • Right
  • View page source

Right

SCPI Command :

CALCulate<n>:DELTamarker<m>:MAXimum:RIGHt
Commands in total: 1
Subgroups: 0
Direct child commands: 1
set(window=Window.Default, deltaMarker=DeltaMarker.Default, opc_timeout_ms: int = -1) → None[source]
# CALCulate<n>:DELTamarker<m>:MAXimum:RIGHt
driver.applications.k9X11Ad.calculate.deltaMarker.maximum.right.set(window = repcap.Window.Default, deltaMarker = repcap.DeltaMarker.Default)

Moves a delta marker to the next positive peak value on the trace. The search includes only measurement values to the right of the current marker position. In the spectrogram, the command moves a marker horizontally to the maximum level in the currently selected frame. The vertical marker position remains the same.

Parameters:
  • window – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)

  • deltaMarker – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘DeltaMarker’)

  • opc_timeout_ms – Maximum time to wait in milliseconds, valid only for this call.

Previous Next