Immediate

SCPI Command :

CONFigure:BURSt:EVM:EVCHip[:IMMediate]
class ImmediateCls[source]

Immediate commands group definition. 1 total commands, 0 Subgroups, 1 group commands

set(opc_timeout_ms: int = - 1) None[source]
# SCPI: CONFigure:BURSt:EVM:EVCHip[:IMMediate]
driver.applications.k91Wlan.configure.burst.evm.evChip.immediate.set()

Both of these commands configure the measurement type to be ‘EVM vs Chip’ for IEEE 802.11b and g (DSSS) standards. For compatibility reasons, the method RsFsw.Applications.K91_Wlan.Configure.Burst.Evm.Esymbol.Immediate.set command is also supported for the IEEE 802.11b and g (DSSS) standards. However, for new remote control programs use the LAYout commands (see ‘Working with windows in the display’) . Results are only displayed after a measurement is executed, e.g. using the method RsFsw.Applications.K10x_Lte.Initiate.Immediate.set command. Note that the CONF:BURS:<ResultType>:IMM commands change the screen layout to display the ‘Magnitude Capture’ buffer in window 1 at the top of the screen and the selected result type in window 2 below that. Any other active windows are closed. Use the LAYout commands to change the display (see ‘Working with windows in the display’) .

param opc_timeout_ms

Maximum time to wait in milliseconds, valid only for this call.