Value

SCPI Command :

CALCulate<n>:LIMit:MACCuracy:FERRor:PMEan:VALue
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(window=Window.Default) float[source]
# CALCulate<n>:LIMit:MACCuracy:FERRor:PMEan:VALue
value: float = driver.applications.k70Vsa.calculate.limit.maccuracy.freqError.pmean.value.get(window = repcap.Window.Default)

Defines the value for the current, peak or mean frequency error (peak or RMS) limit. Note that the limits for the current and the peak value are always kept identical. Is available for FSK modulation only.

Parameters:

window – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)

Returns:

limit_value: the value x (x0) defines the interval [-x; x] Range: 0.0 to 100, Unit: Hz

set(limit_value: float, window=Window.Default) None[source]
# CALCulate<n>:LIMit:MACCuracy:FERRor:PMEan:VALue
driver.applications.k70Vsa.calculate.limit.maccuracy.freqError.pmean.value.set(limit_value = 1.0, window = repcap.Window.Default)

Defines the value for the current, peak or mean frequency error (peak or RMS) limit. Note that the limits for the current and the peak value are always kept identical. Is available for FSK modulation only.

Parameters:
  • limit_value – the value x (x0) defines the interval [-x; x] Range: 0.0 to 100, Unit: Hz

  • window – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)