State
SCPI Command :
CALCulate<n>:HOPDetection:TABLe:PHASe:ALL[:STATe]
- class StateCls[source]
State commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- set(state: bool, scaling: Optional[RsFsw.enums.AngleUnit] = None, window=Window.Default) None [source]
# SCPI: CALCulate<n>:HOPDetection:TABLe:PHASe:ALL[:STATe] driver.applications.k60Transient.calculate.hopDetection.table.phase.all.state.set(state = False, scaling = enums.AngleUnit.DEG, window = repcap.Window.Default)
If enabled, all phase deviation parameters are included in the result tables (see ‘Phase parameters’) . Note that only the enabled columns are returned for the method RsFsw.Applications.K60_Transient.Calculate.HopDetection.Table.Results. get_ query.
- param state
ON | OFF | 0 | 1 OFF | 0 Switches the function off ON | 1 Switches the function on
- param scaling
DEG | RAD Defines the scaling for the phase parameters
- param window