End

SCPI Command :

CALCulate<n>:HOPDetection:POWer:OFFSet:END
class EndCls[source]

End commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get(window=Window.Default) float[source]
# SCPI: CALCulate<n>:HOPDetection:POWer:OFFSet:END
value: float = driver.applications.k60Transient.calculate.hopDetection.power.offset.end.get(window = repcap.Window.Default)

Defines the end of the measurement range as an offset in seconds from the hop end. This command is only available if the reference is EDGE (see method RsFsw.Applications.K60_Transient.Calculate.HopDetection.Power.Reference.set) . For details on the measurement range parameters see ‘Measurement range’.

param window

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)

return

time: Unit: S

set(time: float, window=Window.Default) None[source]
# SCPI: CALCulate<n>:HOPDetection:POWer:OFFSet:END
driver.applications.k60Transient.calculate.hopDetection.power.offset.end.set(time = 1.0, window = repcap.Window.Default)

Defines the end of the measurement range as an offset in seconds from the hop end. This command is only available if the reference is EDGE (see method RsFsw.Applications.K60_Transient.Calculate.HopDetection.Power.Reference.set) . For details on the measurement range parameters see ‘Measurement range’.

param time

Unit: S

param window

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)