End
SCPI Command :
CALCulate<n>:HOPDetection:POWer:OFFSet:END
- class EndCls[source]
End commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(window=Window.Default) float [source]
# SCPI: CALCulate<n>:HOPDetection:POWer:OFFSet:END value: float = driver.applications.k60Transient.calculate.hopDetection.power.offset.end.get(window = repcap.Window.Default)
Defines the end of the measurement range as an offset in seconds from the hop end. This command is only available if the reference is EDGE (see method RsFsw.Applications.K60_Transient.Calculate.HopDetection.Power.Reference.set) . For details on the measurement range parameters see ‘Measurement range’.
- param window
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)
- return
time: Unit: S
- set(time: float, window=Window.Default) None [source]
# SCPI: CALCulate<n>:HOPDetection:POWer:OFFSet:END driver.applications.k60Transient.calculate.hopDetection.power.offset.end.set(time = 1.0, window = repcap.Window.Default)
Defines the end of the measurement range as an offset in seconds from the hop end. This command is only available if the reference is EDGE (see method RsFsw.Applications.K60_Transient.Calculate.HopDetection.Power.Reference.set) . For details on the measurement range parameters see ‘Measurement range’.
- param time
Unit: S
- param window
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)