End
SCPI Command :
CALCulate<n>:HOPDetection:FDEViation:OFFSet:END
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(window=Window.Default) float[source]
# CALCulate<n>:HOPDetection:FDEViation:OFFSet:END value: float = driver.applications.k60Transient.calculate.hopDetection.fdeviation.offset.end.get(window = repcap.Window.Default)
Defines the end of the measurement range for frequency deviation results as an offset in seconds from the hop end. This command is only available if the reference is EDGE (see method
RsFsw.applications.k60Transient.calculate.hopDetection.fdeviation.reference.set()) . For details on the measurement range parameters see ‘Measurement range’.- Parameters:
window – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)
- Returns:
time: Unit: S
- set(time: float, window=Window.Default) None[source]
# CALCulate<n>:HOPDetection:FDEViation:OFFSet:END driver.applications.k60Transient.calculate.hopDetection.fdeviation.offset.end.set(time = 1.0, window = repcap.Window.Default)
Defines the end of the measurement range for frequency deviation results as an offset in seconds from the hop end. This command is only available if the reference is EDGE (see method
RsFsw.applications.k60Transient.calculate.hopDetection.fdeviation.reference.set()) . For details on the measurement range parameters see ‘Measurement range’.- Parameters:
time – Unit: S
window – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)