RsFsw

Contents:

  • Revision History
  • Getting Started
  • Enums
  • RepCaps
  • Examples
  • RsFsw API Structure
    • Applications
      • IqAnalyzer
      • K10x_Lte
      • K149_Uwb
      • K14x_Nr5G
      • K17_Mcgd
      • K18_AmplifierEt
      • K30_NoiseFigure
      • K40_PhaseNoise
      • K50_Spurious
        • Calculate<Window>
        • Calibration
        • Display
        • Fetch
        • FormatPy
        • Initiate
        • InputPy
        • Layout
        • MassMemory
        • Output
        • Read
        • Sense
          • Adjust
          • Correction
          • Creference
          • Directed
          • Fplan
          • ListPy
          • Mixer
          • Pmeter<PowerMeter>
            • Dcycle
            • Frequency
              • Link
            • Mtime
            • Roffset
            • Soffset
            • State
            • Trigger
            • Update
          • Probe<Probe>
          • Ssearch
          • Transfer
        • System
        • Trace<Window>
        • Trigger
        • TriggerInvoke
        • Unit
      • K6_Pulse
      • K60_Transient
      • K7_AnalogDemod
      • K70_Vsa
      • K91_Wlan
      • K9x_11ad
    • Calculate<Window>
    • Calibration
    • Configure
    • Diagnostic
    • Display
    • Fetch
    • FormatPy
    • HardCopy
    • Initiate
    • InputPy<InputIx>
    • Instrument
    • Layout
    • MassMemory
    • Output<OutputConnector>
    • Read
    • Sense
    • Source
    • Status
    • System
    • Trace<Window>
    • Trigger
    • TriggerInvoke
    • Unit
  • RsFsw Utilities
  • RsFsw Logger
  • RsFsw Events
  • Index
RsFsw
  • »
  • RsFsw API Structure »
  • Applications »
  • K50_Spurious »
  • Sense »
  • Pmeter<PowerMeter> »
  • Frequency »
  • Link
  • View page source

Link

SCPI Command :

[SENSe]:PMETer<p>:FREQuency:LINK
class LinkCls[source]

Link commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get(powerMeter=PowerMeter.Default) → RsFsw.enums.PmeterFreqLink[source]
# SCPI: [SENSe]:PMETer<p>:FREQuency:LINK
value: enums.PmeterFreqLink = driver.applications.k50Spurious.sense.pmeter.frequency.link.get(powerMeter = repcap.PowerMeter.Default)

Selects the frequency coupling for power sensor measurements.

param powerMeter

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Pmeter’)

return

arg_0: No help available

set(arg_0: RsFsw.enums.PmeterFreqLink, powerMeter=PowerMeter.Default) → None[source]
# SCPI: [SENSe]:PMETer<p>:FREQuency:LINK
driver.applications.k50Spurious.sense.pmeter.frequency.link.set(arg_0 = enums.PmeterFreqLink.CENTer, powerMeter = repcap.PowerMeter.Default)

Selects the frequency coupling for power sensor measurements.

param arg_0

No help available

param powerMeter

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Pmeter’)

Previous Next

© Copyright © Rohde & Schwarz 2023.

Built with Sphinx using a theme provided by Read the Docs.