Attenuation
SCPI Command :
[SENSe]:LIST:RANGe<ri>:INPut:ATTenuation
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(rangePy=RangePy.Default) float[source]
# [SENSe]:LIST:RANGe<ri>:INPut:ATTenuation value: float = driver.applications.k50Spurious.sense.listPy.range.inputPy.attenuation.get(rangePy = repcap.RangePy.Default)
Defines the input attenuation for a spurious emission measurement range. The sweep list cannot be configured using remote commands during an on-going sweep operation.
- Parameters:
rangePy – optional repeated capability selector. Default value: Ix1 (settable in the interface ‘Range’)
- Returns:
attenuation: Numeric value. Refer to the specifications document for the attenuation range. Unit: dB
- set(attenuation: float, rangePy=RangePy.Default) None[source]
# [SENSe]:LIST:RANGe<ri>:INPut:ATTenuation driver.applications.k50Spurious.sense.listPy.range.inputPy.attenuation.set(attenuation = 1.0, rangePy = repcap.RangePy.Default)
Defines the input attenuation for a spurious emission measurement range. The sweep list cannot be configured using remote commands during an on-going sweep operation.
- Parameters:
attenuation – Numeric value. Refer to the specifications document for the attenuation range. Unit: dB
rangePy – optional repeated capability selector. Default value: Ix1 (settable in the interface ‘Range’)