TypePy
SCPI Command :
[SENSe]:LIST:RANGe<hd>:FILTer:TYPE
- class TypePyCls[source]
TypePy commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(halfDecadeRange=HalfDecadeRange.Default) RsFsw.enums.SweepModeHalfDec [source]
# SCPI: [SENSe]:LIST:RANGe<hd>:FILTer:TYPE value: enums.SweepModeHalfDec = driver.applications.k40PhaseNoise.sense.listPy.range.filterPy.typePy.get(halfDecadeRange = repcap.HalfDecadeRange.Default)
Selects the sweep mode for a particular half decade.
- param halfDecadeRange
optional repeated capability selector. Default value: Rng_1Hz_3Hz (settable in the interface ‘Range’)
- return
mode: NORMal Measurement based on spectrum analyzer data. FFT Measurement based on spectrum analyzer data. Kept for compatibility to R&S FSV. IQFFt Measurement based on I/Q data.
- set(mode: RsFsw.enums.SweepModeHalfDec, halfDecadeRange=HalfDecadeRange.Default) None [source]
# SCPI: [SENSe]:LIST:RANGe<hd>:FILTer:TYPE driver.applications.k40PhaseNoise.sense.listPy.range.filterPy.typePy.set(mode = enums.SweepModeHalfDec.FFT, halfDecadeRange = repcap.HalfDecadeRange.Default)
Selects the sweep mode for a particular half decade.
- param mode
NORMal Measurement based on spectrum analyzer data. FFT Measurement based on spectrum analyzer data. Kept for compatibility to R&S FSV. IQFFt Measurement based on I/Q data.
- param halfDecadeRange
optional repeated capability selector. Default value: Rng_1Hz_3Hz (settable in the interface ‘Range’)