Hot#
SCPI Command :
- CALCulate<n>:UNCertainty:ENR:UNCertainty:HOT
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get ( window=Window.Default ) float
- set ( uncertainty: float, window=Window.Default ) None
# CALCulate<n>:UNCertainty:ENR:UNCertainty:HOT # get: value: float = driver.applications.k30NoiseFigure.calculate.uncertainty.enr.uncertainty.hot.get(window = repcap.Window.Default) # set: driver.applications.k30NoiseFigure.calculate.uncertainty.enr.uncertainty.hot.set(uncertainty = 1.0, window = repcap.Window.Default)
Defines the uncertainty of a resistor. If the noise sources during calibration and measurement are different, the command defines the uncertainty of the measurement noise source.
- Parameters:
uncertainty – Hot temperature uncertainty value of the noise source. Refer to the specifications document of the noise source to determine its uncertainty.
window – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)