Mode

SCPI Command :

DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:MODE
class ModeCls[source]

Mode commands group definition. 2 total commands, 1 Subgroups, 1 group commands

get(window=Window.Default, subWindow=SubWindow.Default, trace=Trace.Default) RsFsw.enums.TraceModeG[source]
# SCPI: DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:MODE
value: enums.TraceModeG = driver.applications.k14Xnr5G.display.window.subwindow.trace.mode.get(window = repcap.Window.Default, subWindow = repcap.SubWindow.Default, trace = repcap.Trace.Default)

Selects the trace mode. If necessary, the selected trace is also activated. For max hold, min hold or average trace mode, you can set the number of single measurements with [SENSe:]SWEep:COUNt. Note that synchronization to the end of the measurement is possible only in single sweep mode. Depending on the result display, not all trace modes are available. For the Magnitude Overview Absolute and the Magnitude Absolute (Selected CB) result displays, only the trace modes ‘Clear/ Write’ and ‘View’ are available. For more information, see ‘Analyzing Several Traces - Trace Mode’.

param window

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Window’)

param subWindow

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Subwindow’)

param trace

optional repeated capability selector. Default value: Tr1 (settable in the interface ‘Trace’)

return

trace_mode: WRITe (default:) Overwrite mode: the trace is overwritten by each sweep. AVERage The average is formed over several sweeps. The ‘Sweep/Average Count’ determines the number of averaging procedures. MAXHold The maximum value is determined over several sweeps and displayed. The FSW saves the sweep result in the trace memory only if the new value is greater than the previous one. MINHold The minimum value is determined from several measurements and displayed. The FSW saves the sweep result in the trace memory only if the new value is lower than the previous one. VIEW The current contents of the trace memory are frozen and displayed. BLANk Hides the selected trace. DENSity The occurrence of each value within the current result range or evaluation range is indicated by color. This trace mode is only available for constellation, vector, and eye diagrams.

set(trace_mode: RsFsw.enums.TraceModeG, window=Window.Default, subWindow=SubWindow.Default, trace=Trace.Default) None[source]
# SCPI: DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:MODE
driver.applications.k14Xnr5G.display.window.subwindow.trace.mode.set(trace_mode = enums.TraceModeG.AVERage, window = repcap.Window.Default, subWindow = repcap.SubWindow.Default, trace = repcap.Trace.Default)

Selects the trace mode. If necessary, the selected trace is also activated. For max hold, min hold or average trace mode, you can set the number of single measurements with [SENSe:]SWEep:COUNt. Note that synchronization to the end of the measurement is possible only in single sweep mode. Depending on the result display, not all trace modes are available. For the Magnitude Overview Absolute and the Magnitude Absolute (Selected CB) result displays, only the trace modes ‘Clear/ Write’ and ‘View’ are available. For more information, see ‘Analyzing Several Traces - Trace Mode’.

param trace_mode

WRITe (default:) Overwrite mode: the trace is overwritten by each sweep. AVERage The average is formed over several sweeps. The ‘Sweep/Average Count’ determines the number of averaging procedures. MAXHold The maximum value is determined over several sweeps and displayed. The FSW saves the sweep result in the trace memory only if the new value is greater than the previous one. MINHold The minimum value is determined from several measurements and displayed. The FSW saves the sweep result in the trace memory only if the new value is lower than the previous one. VIEW The current contents of the trace memory are frozen and displayed. BLANk Hides the selected trace. DENSity The occurrence of each value within the current result range or evaluation range is indicated by color. This trace mode is only available for constellation, vector, and eye diagrams.

param window

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Window’)

param subWindow

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Subwindow’)

param trace

optional repeated capability selector. Default value: Tr1 (settable in the interface ‘Trace’)

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.applications.k14Xnr5G.display.window.subwindow.trace.mode.clone()

Subgroups