Source
SCPI Command :
[SENSe]:SWEep:EGATe:SOURce
- class SourceCls[source]
Source commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get() RsFsw.enums.GatedSourceLte [source]
# SCPI: [SENSe]:SWEep:EGATe:SOURce value: enums.GatedSourceLte = driver.applications.k10Xlte.sense.sweep.egate.source.get()
Selects the signal source for gated measurements. If an IF power signal is used, the gate is opened as soon as a signal at > -20 dBm is detected within the IF path bandwidth (10 MHz) . For more information see ‘Trigger Source’.
INTRO_CMD_HELP: For triggered gated measurements,only the following gate trigger sources are supported:
‘External Trigger 1/2/3’
‘Power Sensor’
For details see ‘Triggered gated measurements’
- return
source: EXTernal | EXT2 | EXT3 | IFPower | IQPower | VIDeo | RFPower | PSEN
- set(source: RsFsw.enums.GatedSourceLte) None [source]
# SCPI: [SENSe]:SWEep:EGATe:SOURce driver.applications.k10Xlte.sense.sweep.egate.source.set(source = enums.GatedSourceLte.EXT2)
Selects the signal source for gated measurements. If an IF power signal is used, the gate is opened as soon as a signal at > -20 dBm is detected within the IF path bandwidth (10 MHz) . For more information see ‘Trigger Source’.
INTRO_CMD_HELP: For triggered gated measurements,only the following gate trigger sources are supported:
‘External Trigger 1/2/3’
‘Power Sensor’
For details see ‘Triggered gated measurements’
- param source
EXTernal | EXT2 | EXT3 | IFPower | IQPower | VIDeo | RFPower | PSEN