Stop
SCPI Command :
[SENSe]:ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STOP
- class StopCls[source]
Stop commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(subBlock=SubBlock.Default, rangePy=RangePy.Default, limitIx=LimitIx.Default) float [source]
# SCPI: [SENSe]:ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STOP value: float = driver.applications.k10Xlte.sense.espectrum.range.limit.relative.stop.get(subBlock = repcap.SubBlock.Default, rangePy = repcap.RangePy.Default, limitIx = repcap.LimitIx.Default)
Defines a relative limit for a SEM range. Unlike manual operation, you can define a relative limit anytime and regardless of the limit check mode.
- param subBlock
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Espectrum’)
- param rangePy
optional repeated capability selector. Default value: Ix1 (settable in the interface ‘Range’)
- param limitIx
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Limit’)
- return
limit: No help available
- set(limit: float, subBlock=SubBlock.Default, rangePy=RangePy.Default, limitIx=LimitIx.Default) None [source]
# SCPI: [SENSe]:ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STOP driver.applications.k10Xlte.sense.espectrum.range.limit.relative.stop.set(limit = 1.0, subBlock = repcap.SubBlock.Default, rangePy = repcap.RangePy.Default, limitIx = repcap.LimitIx.Default)
Defines a relative limit for a SEM range. Unlike manual operation, you can define a relative limit anytime and regardless of the limit check mode.
- param limit
No help available
- param subBlock
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Espectrum’)
- param rangePy
optional repeated capability selector. Default value: Ix1 (settable in the interface ‘Range’)
- param limitIx
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Limit’)