Mode
SCPI Command :
[SENSe]:IQ:BANDwidth:MODE
- class ModeCls[source]
Mode commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get() RsFsw.enums.IqBandwidthMode [source]
# SCPI: [SENSe]:IQ:BANDwidth:MODE value: enums.IqBandwidthMode = driver.applications.iqAnalyzer.sense.iq.bandwidth.mode.get()
Defines how the resolution bandwidth is determined.
- return
mode: AUTO | MANual | FFT AUTO (Default) The RBW is determined automatically depending on the sample rate and record length. MANual The user-defined RBW is used and the (FFT) window length (and possibly the sample rate) are adapted accordingly. The RBW is defined using the [SENSe:]IQ:BWIDth:RESolution command. FFT The RBW is determined by the FFT parameters.
- set(mode: RsFsw.enums.IqBandwidthMode) None [source]
# SCPI: [SENSe]:IQ:BANDwidth:MODE driver.applications.iqAnalyzer.sense.iq.bandwidth.mode.set(mode = enums.IqBandwidthMode.AUTO)
Defines how the resolution bandwidth is determined.
- param mode
AUTO | MANual | FFT AUTO (Default) The RBW is determined automatically depending on the sample rate and record length. MANual The user-defined RBW is used and the (FFT) window length (and possibly the sample rate) are adapted accordingly. The RBW is defined using the [SENSe:]IQ:BWIDth:RESolution command. FFT The RBW is determined by the FFT parameters.