Source code for RsSmw.Implementations.Source.Bb.Evdo.User.Drclock.Length

from .......Internal.Core import Core
from .......Internal.CommandsGroup import CommandsGroup
from .......Internal import Conversions
from ....... import enums
from ....... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class LengthCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("length", core, parent)

[docs] def set(self, length: enums.EvdoDrcLenDn, userIx=repcap.UserIx.Default) -> None: """ ``[SOURce<HW>]:BB:EVDO:USER<ST>:DRCLock:LENGth`` \n Snippet: ``driver.source.bb.evdo.user.drclock.length.set(length = enums.EvdoDrcLenDn.DL1, userIx = repcap.UserIx.Default)`` \n Sets the number of DRC (Data Rate Control) Lock periods that the state of the DRC Lock for the selected user is held constant. Note: Changes in the DRC Lock state are only considered at the interval defined by the parameter DRC Lock Length. A value of one allows updating of the DRC Lock bit at anytime. :param length: DL1 | DL4 | DL8 | DL16 | DL32 | DL64 :param userIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'User') """ param = Conversions.enum_scalar_to_str(length, enums.EvdoDrcLenDn) userIx_cmd_val = self._cmd_group.get_repcap_cmd_value(userIx, repcap.UserIx) self._core.io.write(f'SOURce<HwInstance>:BB:EVDO:USER{userIx_cmd_val}:DRCLock:LENGth {param}')
# noinspection PyTypeChecker
[docs] def get(self, userIx=repcap.UserIx.Default) -> enums.EvdoDrcLenDn: """ ``[SOURce<HW>]:BB:EVDO:USER<ST>:DRCLock:LENGth`` \n Snippet: ``value: enums.EvdoDrcLenDn = driver.source.bb.evdo.user.drclock.length.get(userIx = repcap.UserIx.Default)`` \n Sets the number of DRC (Data Rate Control) Lock periods that the state of the DRC Lock for the selected user is held constant. Note: Changes in the DRC Lock state are only considered at the interval defined by the parameter DRC Lock Length. A value of one allows updating of the DRC Lock bit at anytime. :param userIx: optional repeated capability selector. Default value: Nr1 (settable in the interface 'User') :return: length: DL1 | DL4 | DL8 | DL16 | DL32 | DL64 """ userIx_cmd_val = self._cmd_group.get_repcap_cmd_value(userIx, repcap.UserIx) response = self._core.io.query_str(f'SOURce<HwInstance>:BB:EVDO:USER{userIx_cmd_val}:DRCLock:LENGth?') return Conversions.str_to_scalar_enum(response, enums.EvdoDrcLenDn)