Source code for RsSmw.Implementations.Source.Bb.Eutra.Uplink.Ue.Sl.Sci.FreqResloc

from .........Internal.Core import Core
from .........Internal.CommandsGroup import CommandsGroup
from .........Internal import Conversions
from ......... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class FreqReslocCls: """FreqResloc commands group definition. 1 total commands, 0 Subgroups, 1 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("freqResloc", core, parent)
[docs] def set(self, freq_res_location: int, userEquipment=repcap.UserEquipment.Default, indexNull=repcap.IndexNull.Default) -> None: """SCPI: [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:SL:SCI<CH0>:FREQresloc \n Snippet: driver.source.bb.eutra.uplink.ue.sl.sci.freqResloc.set(freq_res_location = 1, userEquipment = repcap.UserEquipment.Default, indexNull = repcap.IndexNull.Default) \n Sets the frequency resource location of initial transmission and retransmission field. \n :param freq_res_location: integer Range: 0 to 255 :param userEquipment: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Ue') :param indexNull: optional repeated capability selector. Default value: Nr0 (settable in the interface 'Sci') """ param = Conversions.decimal_value_to_str(freq_res_location) userEquipment_cmd_val = self._cmd_group.get_repcap_cmd_value(userEquipment, repcap.UserEquipment) indexNull_cmd_val = self._cmd_group.get_repcap_cmd_value(indexNull, repcap.IndexNull) self._core.io.write(f'SOURce<HwInstance>:BB:EUTRa:UL:UE{userEquipment_cmd_val}:SL:SCI{indexNull_cmd_val}:FREQresloc {param}')
[docs] def get(self, userEquipment=repcap.UserEquipment.Default, indexNull=repcap.IndexNull.Default) -> int: """SCPI: [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:SL:SCI<CH0>:FREQresloc \n Snippet: value: int = driver.source.bb.eutra.uplink.ue.sl.sci.freqResloc.get(userEquipment = repcap.UserEquipment.Default, indexNull = repcap.IndexNull.Default) \n Sets the frequency resource location of initial transmission and retransmission field. \n :param userEquipment: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Ue') :param indexNull: optional repeated capability selector. Default value: Nr0 (settable in the interface 'Sci') :return: freq_res_location: integer Range: 0 to 255""" userEquipment_cmd_val = self._cmd_group.get_repcap_cmd_value(userEquipment, repcap.UserEquipment) indexNull_cmd_val = self._cmd_group.get_repcap_cmd_value(indexNull, repcap.IndexNull) response = self._core.io.query_str(f'SOURce<HwInstance>:BB:EUTRa:UL:UE{userEquipment_cmd_val}:SL:SCI{indexNull_cmd_val}:FREQresloc?') return Conversions.str_to_int(response)