Source code for RsSmw.Implementations.Source.Bb.Dvb.Dvbr.SfConfig.FrConfig.Btu.TuCount

from .........Internal.Core import Core
from .........Internal.CommandsGroup import CommandsGroup
from .........Internal import Conversions
from ......... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class TuCountCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("tuCount", core, parent)

[docs] def set(self, tu_count: int, sfCfgIxNull=repcap.SfCfgIxNull.Default, frCfgIxNull=repcap.FrCfgIxNull.Default) -> None: """ ``[SOURce<HW>]:BB:DVB:DVBR:SFConfig<CH0>:FRConfig<S0T>:BTU:TUCount`` \n Snippet: ``driver.source.bb.dvb.dvbr.sfConfig.frConfig.btu.tuCount.set(tu_count = 1, sfCfgIxNull = repcap.SfCfgIxNull.Default, frCfgIxNull = repcap.FrCfgIxNull.Default)`` \n Sets the number of consecutive BTUs within a frame. :param tu_count: integer Range: 1 to 24 :param sfCfgIxNull: optional repeated capability selector. Default value: Nr0 (settable in the interface 'SfConfig') :param frCfgIxNull: optional repeated capability selector. Default value: Nr0 (settable in the interface 'FrConfig') """ param = Conversions.decimal_value_to_str(tu_count) sfCfgIxNull_cmd_val = self._cmd_group.get_repcap_cmd_value(sfCfgIxNull, repcap.SfCfgIxNull) frCfgIxNull_cmd_val = self._cmd_group.get_repcap_cmd_value(frCfgIxNull, repcap.FrCfgIxNull) self._core.io.write(f'SOURce<HwInstance>:BB:DVB:DVBR:SFConfig{sfCfgIxNull_cmd_val}:FRConfig{frCfgIxNull_cmd_val}:BTU:TUCount {param}')
[docs] def get(self, sfCfgIxNull=repcap.SfCfgIxNull.Default, frCfgIxNull=repcap.FrCfgIxNull.Default) -> int: """ ``[SOURce<HW>]:BB:DVB:DVBR:SFConfig<CH0>:FRConfig<S0T>:BTU:TUCount`` \n Snippet: ``value: int = driver.source.bb.dvb.dvbr.sfConfig.frConfig.btu.tuCount.get(sfCfgIxNull = repcap.SfCfgIxNull.Default, frCfgIxNull = repcap.FrCfgIxNull.Default)`` \n Sets the number of consecutive BTUs within a frame. :param sfCfgIxNull: optional repeated capability selector. Default value: Nr0 (settable in the interface 'SfConfig') :param frCfgIxNull: optional repeated capability selector. Default value: Nr0 (settable in the interface 'FrConfig') :return: tu_count: integer Range: 1 to 24 """ sfCfgIxNull_cmd_val = self._cmd_group.get_repcap_cmd_value(sfCfgIxNull, repcap.SfCfgIxNull) frCfgIxNull_cmd_val = self._cmd_group.get_repcap_cmd_value(frCfgIxNull, repcap.FrCfgIxNull) response = self._core.io.query_str(f'SOURce<HwInstance>:BB:DVB:DVBR:SFConfig{sfCfgIxNull_cmd_val}:FRConfig{frCfgIxNull_cmd_val}:BTU:TUCount?') return Conversions.str_to_int(response)