Data

SCPI Command :

[SOURce<HW>]:BB:ONEWeb:DL:[SUBF<ST0>]:ALLoc<CH0>:[CW<USER>]:DATA
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(subframeNull=SubframeNull.Default, allocationNull=AllocationNull.Default, codeword=Codeword.Default) OneWebDlDataSourceUser[source]
# [SOURce<HW>]:BB:ONEWeb:DL:[SUBF<ST0>]:ALLoc<CH0>:[CW<USER>]:DATA
value: enums.OneWebDlDataSourceUser = driver.source.bb.oneweb.downlink.subf.alloc.cw.data.get(subframeNull = repcap.SubframeNull.Default, allocationNull = repcap.AllocationNull.Default, codeword = repcap.Codeword.Default)

Queries the data source for the selected allocation.

Parameters:
  • subframeNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Subf’)

  • allocationNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Alloc’)

  • codeword – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cw’)

Returns:

data: USER1 | USER2 | USER3 | USER4 | PN9 | PN11 | PN15 | PN16 | PN20 | PN21 | PN23 | PATTern | DLISt | ZERO | ONE | MIB MIB Returns value indicates that the PBCH transmits real MIB data. See also method RsSmw.source.bb.oneweb.downlink.pbch.mib()