Id
SCPI Command :
[SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:DL:BWP<BWP(DIR0)>:RMC:ID
- class IdCls[source]
Id commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(userNull=UserNull.Default, cellNull=CellNull.Default, bwPartNull=BwPartNull.Default) RsSmw.enums.RmcIdAll [source]
# SCPI: [SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:DL:BWP<BWP(DIR0)>:RMC:ID value: enums.RmcIdAll = driver.source.bb.nr5G.ubwp.user.cell.downlink.bwp.rmc.id.get(userNull = repcap.UserNull.Default, cellNull = repcap.CellNull.Default, bwPartNull = repcap.BwPartNull.Default)
This command selects a reference measurement channel. The availability of RMCs depends on the subcarrier spacing of the bandwidth part you are configuring.
- param userNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)
- param cellNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)
- param bwPartNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Bwp’)
- return
rmc_id: FQ15| FQ30| FQ60| F615| F630| F660| F215| F230| F260| TQ15| TQ30| TQ60| T615| T630| T660| T215| T230| T260| TS38176_FR1A311| TS38176_FR1A312| TS38176_FR1A313| TS38176_FR1A314| TS38176_FR1A315| TS38176_FR2A311| TS38176_FR2A312| TS38176_FR2A313| TS38176_FR1A321| TS38176_FR2A321| TS38176_FR2A322| TS38176_FR1A331| FR2TQ60| FR2TQ120| FR2T660| FR2T6120| FR2T260| FR2T2120| TS38176_FR1A351| TS38176_FR1A352| TS38176_FR1A353| TS38176_FR1A354| TS38176_FR1A355| TS38176_FR1A356| TS38176_FR2A351| TS38176_FR2A352| TS38176_FR2A353| TS38176_FR1A341| TS38176_FR1A342| TS38176_FR1A343| TS38176_FR2A341| TS38176_FR2A342| TS38176_FR2A343 The logic of the labels is as follows: No prefix = 38.521 FR1 RMCs Prefix FR2 = 38.521 FR2 RMCs F / T = duplexing (FDD or TDD) Q / 6 / 2 = modulation (QPSK, 64QAM or 256 QAM) 15 / 30 / 60 = subcarrier spacing (15, 30 or 60 kHz) For example ‘T615’ corresponds to FR1 RMC with the name ‘TS 38.521: A.3.3.3-1 (15 kHz) ‘. The RMCs from 38.176 are basically a shortened form of the names of the RMCs. For example ‘TS38176_FR1A352’ corresponds to RMC with the name ‘TS 38.176: M-FR1-A3_5_2’.
- set(rmc_id: RsSmw.enums.RmcIdAll, userNull=UserNull.Default, cellNull=CellNull.Default, bwPartNull=BwPartNull.Default) None [source]
# SCPI: [SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:DL:BWP<BWP(DIR0)>:RMC:ID driver.source.bb.nr5G.ubwp.user.cell.downlink.bwp.rmc.id.set(rmc_id = enums.RmcIdAll.F215, userNull = repcap.UserNull.Default, cellNull = repcap.CellNull.Default, bwPartNull = repcap.BwPartNull.Default)
This command selects a reference measurement channel. The availability of RMCs depends on the subcarrier spacing of the bandwidth part you are configuring.
- param rmc_id
FQ15| FQ30| FQ60| F615| F630| F660| F215| F230| F260| TQ15| TQ30| TQ60| T615| T630| T660| T215| T230| T260| TS38176_FR1A311| TS38176_FR1A312| TS38176_FR1A313| TS38176_FR1A314| TS38176_FR1A315| TS38176_FR2A311| TS38176_FR2A312| TS38176_FR2A313| TS38176_FR1A321| TS38176_FR2A321| TS38176_FR2A322| TS38176_FR1A331| FR2TQ60| FR2TQ120| FR2T660| FR2T6120| FR2T260| FR2T2120| TS38176_FR1A351| TS38176_FR1A352| TS38176_FR1A353| TS38176_FR1A354| TS38176_FR1A355| TS38176_FR1A356| TS38176_FR2A351| TS38176_FR2A352| TS38176_FR2A353| TS38176_FR1A341| TS38176_FR1A342| TS38176_FR1A343| TS38176_FR2A341| TS38176_FR2A342| TS38176_FR2A343 The logic of the labels is as follows: No prefix = 38.521 FR1 RMCs Prefix FR2 = 38.521 FR2 RMCs F / T = duplexing (FDD or TDD) Q / 6 / 2 = modulation (QPSK, 64QAM or 256 QAM) 15 / 30 / 60 = subcarrier spacing (15, 30 or 60 kHz) For example ‘T615’ corresponds to FR1 RMC with the name ‘TS 38.521: A.3.3.3-1 (15 kHz) ‘. The RMCs from 38.176 are basically a shortened form of the names of the RMCs. For example ‘TS38176_FR1A352’ corresponds to RMC with the name ‘TS 38.176: M-FR1-A3_5_2’.
- param userNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)
- param cellNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)
- param bwPartNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Bwp’)