Dai2
SCPI Command :
[SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:DL:BWP<BWP(DIR0)>:DCI:DAI2
- class Dai2Cls[source]
Dai2 commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(userNull=UserNull.Default, cellNull=CellNull.Default, bwPartNull=BwPartNull.Default) DailEn [source]
# SCPI: [SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:DL:BWP<BWP(DIR0)>:DCI:DAI2 value: enums.DailEn = driver.source.bb.nr5G.ubwp.user.cell.downlink.bwp.dci.dai2.get(userNull = repcap.UserNull.Default, cellNull = repcap.CellNull.Default, bwPartNull = repcap.BwPartNull.Default)
Defines the bit length of the ‘2nd Downlink Assignment Index’ field.
- param userNull:
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)
- param cellNull:
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)
- param bwPartNull:
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Bwp’)
- return:
num_bits_dai_2: No help available
- set(num_bits_dai_2: DailEn, userNull=UserNull.Default, cellNull=CellNull.Default, bwPartNull=BwPartNull.Default) None [source]
# SCPI: [SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:DL:BWP<BWP(DIR0)>:DCI:DAI2 driver.source.bb.nr5G.ubwp.user.cell.downlink.bwp.dci.dai2.set(num_bits_dai_2 = enums.DailEn.L0, userNull = repcap.UserNull.Default, cellNull = repcap.CellNull.Default, bwPartNull = repcap.BwPartNull.Default)
Defines the bit length of the ‘2nd Downlink Assignment Index’ field.
- param num_bits_dai_2:
L0| L2| L4
- param userNull:
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)
- param cellNull:
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)
- param bwPartNull:
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Bwp’)