Time#
SCPI Command :
- [SOURce<HW>]:BB:HUWB:TRIGger:TIME:[STATe]
- Commands in total: 3Subgroups: 2Direct child commands: 1
- get_state ( ) bool
- set_state ( state: bool ) None
# [SOURce<HW>]:BB:HUWB:TRIGger:TIME:[STATe] # get: value: bool = driver.source.bb.huwb.trigger.time.get_state() # set: driver.source.bb.huwb.trigger.time.set_state(state = False)
Activates time-based triggering with a fixed time reference. If activated, the R&S SMW200A triggers signal generation when its operating system time matches a specified time. Specify the trigger date and trigger time with the following commands: SOURce<hw>:BB:<DigStd>:TRIGger:TIME:DATE SOURce<hw>:BB:<DigStd>:TRIGger:TIME:TIME <DigStd> is the mnemonic for the digital standard, for example, ARB. Time-based triggering behaves analogously for all digital standards that support this feature.
- Parameters:
state – 1 | ON | 0| OFF
Cloning the Group
# Create a copy of the original group, that exists independently
time_copy = driver.source.bb.huwb.trigger.time.clone()
Subgroups